Log in to see the plans as drawnEN 858-1:2002 (E) Automatic closure devices shail-be easily maintained. Where closure devices are operated by floats they shall be easily removable and adjustable, and shall be calibrated for light liquids with a density of 0,85 g/cm® or 0,90 g/cm® or 0,95 gicm?, When tested in accordance with 8.3.2 the leakage shall not exceed 100 NS of the separator, in millilitres, during a period of 15 min. Unauthorised removal of the automatic closure device shall be prevented. 6.5.4 Automatic warning devices and additional devices Separator systems shall be provided with automatic warning devices. NOTE Local authorities may allow the use of separators without automatic warning devices. 6.5.5 Separators with a bypass device Where a bypass device is incorporated in a separator system the separator itself shall meet the requirements and tests provided in this standard. The maximum flow rate of the separator related to its nominal size shall not be exceeded. NOTE The characteristics of the bypass device itself are not covered by this standard. 6.5.6 Determination of the nominal size and class 6.5.6.1 Prefabricated separators The nominal size and class of prefabricated separators shall be determined by their performance when tested in accordance with 8.3.3.1. NOTE Prefabricated separators are those which are in whole, or in finished parts, produced in the manufacturers’ workshop. 6.5.6.2 Separators built in-situ Separators built in-situ according to this standard are only permissible in. nominal sizes equal to or greater than NS 150 and their use is subject to the approval of local authorities. When tested in accordance with clause 8 they shall comply with the requirements given in clauses 6 and 7. ) The nomina! size shall be determined @1] as follows: a) by testing in accordance with 8.3.3.1 against models having identical dimensions, components, design and construction characteristics; b) by constructing the separator system in accordance with the following guidelines: The ratio of the width to length of the separator shall be between 1:1,5 and 1:5. The distance between the bottom of the separator and the scumboard or the outlet pipe should be 20 % of the water depth H. The minimum depth Afnin of water shail be 2,5 m including a depth of 0,15 m for the light liquid storage and a depth of 0,35 m for possible sediment collection. From the nominal size NS the minimum surface area Amin, the minimum total volume Vin and the minimum fight liquid storage volume Vj min Can be calculated as follows: Water surface, m?: Amin = 0,2 x NS Total volume, m? : Vain =HXA=0,5XNS Light liquid storage volume, m: V1 min = 0,03 x NS g This is a licensed reproduction produced by SAI Global Ltd, an authorized distributor of British Standards 15
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.