Skip to the record
Search everything, all in one place.

Original source · versioned page text

MCU14/0056 Response to SARA - Consulting Report

of 321

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (24.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 111, section 1. The text section number identifies this passage in the reader.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
EN 858-1:2002 (E)

The calculated values for the nominal sizes NS as well as the minimum nominal diameters DN», of the infet and
ouilet pipes are given in table 3. These separators are considered to be class II only.

Table 3 — Sizing of separators built in-situ

 

 

Minimum water Minimum total volume} Minimum volume of | Minimum diameter of Nominal size
surface area of light liquid storage | inlet and outlet pipes
separator chamber
Amin Venn V; min DNmin NS
3 3
m2 m m
30 75 45 400 150
40 400 6,0 400 200
60 150 9,0 500 300
80 200 12,0 500 400
100 250 15,0 600 500

 

 

 

 

 

 

 

6.6 Marking

6.6.1 Separator systems

The covers of separator systems shall be marked with "Separator", together with the class of cover in accordance
with EN 124. Furthermore, nameplates in a durable material e. g. stainless steel, shall be fixed to the separators in
a Clearly visible position, if possible on the inside.

If a separator and sludge trap are combined, a nameplate on the entrance to the separator manhole, or, on
exposed installations, on the separator itself is acceptable. if a separator and sludge trap are separate units a
nameplate for each is recommended.

The nameplate shall contain the following information:

— EN 858;

— class (I or il);

— _ nominal size (NS);

— volume of the separator, in I or m°

— volume of the sludge trap, in | or m*

— storage capacity for light liquids, in | or m?:

— depth of maximum storage quantity, in mm;

— _ year of manufacture;

-—~ manufacturer's name or mark;

-— mark of acertification body, where applicable.

Further marking may be added. Where ZA.3 covers the same information as this Clause, the requirements of
this Clause are met.

416 This is a licensed reproduction produced by SAI Global Ltd, an authorized distributor of British Standards
Log in to download the original file

MCU14_0056 Response to SARA - Consulting Report.pdf · 24.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.