Original PDF page 128, section 1. The text section number identifies this passage in the reader.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
Table 5 (continued)

EN 858-1:2002 (E)

 

Aspects to be tested

Test method/evaluation of
conformity according to

Nature and number of samples,
test specimens and
measurements

Requirements
according to

 

Chemical resistance of internal
surfaces:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

— Plastics materials and linings |8.1.4.2 Three test specimens according |6.2.7.1.2
to 8.1.4.2 per material type
— Sealing maierials 8.1.4.3 According to {SO 1817 6.2.7.1.3
— Coatings 8.1.4.4 Three steel test specimens 6.2.7.1.4
according to 8.1.3.2.6 per test
Chemical resistance of 8.1.5- Three test specimens according |6.2.7.2
external surfaces ‘to 8.1.3.2.6 per test
Dimensions of chambers and |Measurement for Prototype separator system 9.2
components compliance with
manufacturer's
documentation
Maximum operational liquid Procedures in 8.3.3.1.3 Prototype separator 3.11; 6.3.1
level and area of the separator
or sludge trap
Watertightness of components |8.2 Prototype separator system and |6.3.2
where necessary test apparatus
according to figure 1
Accessibility Visual inspection and Prototype separator system 6.3.3
measurement
Water seals Measurement Prototype separator system 6.3.4
Pipes and pipe joints Visual inspection and Prototype separator system 6.3.5
measurement
Internal components Visual inspection, test by |Prototype separator system 6.3.6
way of trial
Sludge trap Visual inspection Prototype separator system 6.3.7
Access covers Visual inspection Prototype separator system 6.3.8
Reaction to fire 8.4.2 Material test 6.2.8
Structural stability Verification of existence of 6.4
documents showing
compliance with 6.4
Functional requirements:
— General Verification on the basis of 6.5.1
the drawings
— Storage capacity for light Determination in 6.5.2
liquids accordance with 8.3.3.1.3
— Automatic closure device 8.3.2 Prototype separator or separate |6.5.3
tank
— Automatic warning Verify existence of Prototype separator system 6.5.4
devices/additional devices certificates
— Bypass separator All tests concerning the Prototype separator system 6.5.5

 

This is a licensed reproduction produced by SAl Global Ltd, an authorized distributor of British Standards

33
Log in to download the original file

MCU14_0056 Response to SARA - Consulting Report.pdf · 24.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.