Skip to the record
Noosa’s premier civic archive.

Original source · versioned page text

MCU14/0056 Response to SARA - Consulting Report

of 321

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (24.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 176, section 1. The text section number identifies this passage in the reader.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
Oil separator alarm device                           DATA SHEET                                                          20.11.2007
                                                                                                                         D15369_e
OilSET-1000
1. General
                                                           2. Technical data
The OilSET-1000 level alarm instrument is
                                                           OilSET-1000 control unit
specially designed for oil separators and
grease traps. It indicates when it is time to              Dimensions                     175 mm x 125 mm x 75 mm (L x H x D)

empty the oil separator and thus prevents                  Enclosure                      IP 65, material polycarbonate
harmful hydrocarbon emissions to the sewer                 Ambient temperature            -25 ºC…+50 ºC
system.                                                    Supply voltage                 230 VAC ± 10 %, 50/60 Hz
                                                                                          Fuse 5 x 20 mm 125 mAT (EN 60127-2/3)
                                                                                          The device is not equipped with a mains
                                                                                          switch

                                                           Power consumption              2 VA

                                                           Probes                         One Labkotec SET probe (SET DM/3)

                                                           Max. impedance of the          75 Ω.
                                                           current loop between
                                                           the control unit and a
                                                           probe

                                                           Relay outputs                  Two potential-free relay outputs
                                                                                          250 V, 5 A, 100 VA
                                                                                          Operational delay 5 sec or 30 sec. Relays de-
                                                                                          energize at trigger point. Operation mode
                                                                                          selectable for increasing or decreasing level.

Fig. 1. OilSET-1000 separator alarm unit                   Electrical safety              EN 61010-1, Class II       , CAT II / III

                                                           Insulation level               375V (EN 50020)
                                                           Probe / Mains supply
                                                           voltage


                                                           EMC
                                                                           Emission       EN 61000-6-3
           OilSET-1000                                                     Immunity       EN 61000-6-2
            control unit
                                                           Ex-classification                  II (1) G [EEx ia] IIC
                                                                                              VTT 04 ATEX 031X
                                                           Special conditions (X)             (Ta = -25 °C…+50 °C)

                                                           Electrical parameters          Uo = 14,7 V       Io = 55 mA
                                                                                          Po = 297 mW       R = 404 Ω
                                                           Characteristic curve of
                                                           the output voltage is
    Oil        SET DM/3                                    trapezoidal
                 probe

                                                           SET DM/3 probe
   Water
                                                           Principle of operation           Measurement of conductivity

                                                           Enclosure                        IP68, materials: AISI 316 and PVC

                                                           Ambient temperature              -20 ºC…+70 ºC

Fig. 2. Identification of a oil layer from the separator   Supply voltage                   Approx. 12 VDC from SET control unit

                                                           Cable                            Fixed oil resistant PVC cable 3 x 0,5 mm2,
                                                                                            standard length 5 m.

                                                           EMC
                                                                               Emission     EN 50081-1
                                                                               Immunity     EN 50082-1

                                                           Ex-classification                      II 1 G EEx ia IIA T4
                                                                                                  VTT 02 ATEX 012X

                                                           Electrical parameters            Ui = 16,5 V      Ii = 80 mA
                                                                                            Pi = 330 mW      Ci = 700 pF
                                                                                            Li = 10 μH
Log in to download the original file

MCU14_0056 Response to SARA - Consulting Report.pdf · 24.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.