Log in to see the plans as drawn 2.0 Proposed Solution: SPEL Puraceptor
The SPEL Puraceptor is a full retention oil separator that treats the runoff generated in the service stations.
It is sized to contain more than the anticipated maximum oil spillage (industry standard practice is 8,000L)
enabling it to be fully operational at all times. The flow tests conducted by the University of South Australia
Hydraulics Research Laboratory (UniSA) and at HR Wallingford United Kingdom confirms that the unit
complies with the European Standard BS EN 858.1.2006. The Australian Runoff Quality Handbook (ARQ)
makes several references to the BS EN 858.1.2006 standard in chapter 9 (Hydrocarbon Management). It
achieves a water discharge quality of less than 5 mg light liquids per litre complying with European
Standard BS EN 858 (Appendix 1). Treatable flow rates range from 2 L/sec to 200 L/sec and its pipe sizes
range from 100mm to 450mm. SPEL Puraceptor units are glass reinforced plastic vessels made by the
technical advanced chop hoop filament winding process (patented) producing circumferential and
longitudinal strength complying with BS4994 FRP Pressure Vessel code and AS 2634FRP Chemical
Equipment to ensure the construction meets the necessary strength and stability requirements. The tank is
designed to accept ground conditions with low stiffness down to 4.8MPa, water tables are set to ground
level as standard with a minimum depth of cover, based on a standard soil density.
The treatment efficiency in SPEL Puraceptor Class 1 is:
>99.9% hydrocarbons reduction
>97% sediment reduction for median particle size distribution 70µm
SPEL Puraceptors are easy and safe to clean and maintain, with provision to both chambers through
manholes conveniently placed for vacuum - loading truck access. Cleaning is performed by personnel
from outside the tank. No entering of the tank is required, satisfying OH&S requirements.
The SPEL Puraceptor has many unique benefits and covers a broad duty range, making it the obvious
choice to avert runoff contamination, and treat hydrocarbon and TSS runoff. Some of the excellent
benefits include:
Suitable to discharge to local rivers and streams;
Approved to the stringent European Standard BS EN 858.1 2006;
Complies with the Department of Environment Climate Change Water of NSW [DECCW] for
stormwater quality;
Lightweight fibreglass horizontal construction;
Complying with ANZECC 2000 Guidelines;
Complying with the standards of Department of Environment and Resource Management of QLD
[DERM];
Complying with Environmental Protection Agency [EPA] of South Australia, Northern Territory,
Tasmania & Victoria;
Australian and New Zealand Environment Conservation Council Guidelines for recreational water
quality and aesthetics (Chapter 5);
Complying with the Australian Airport [Federal] Environmental Protection Act;
Complying with the “no visible trace or sheen of oil or grease on released waters” condition force
by the Department of Water;
Duty range 2L/sec - 200L/sec;
HEAD OFFICE POSTAL EMAIL ABN spel.com.au
100 Silverwater Road PO BOX 7138 [email protected] 83 151 832 629
Silverwater NSW 2128 Silverwater NSW 2128
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.