Skip to the record
For the highest quality transcripts.

Original source · versioned page text

MCU14/0056 Response to SARA - Consulting Report

of 321

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (24.7 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Original PDF page 84, section 1. The text section number identifies this passage in the reader.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
          Installation
          The control unit has been designed to be located indoors and outdoors. It should be wall mounted and
          positioned such that the LED display and push switches on the front panel can be readily seen and
          accessed. The unit can be secured to the wall by using the four mounting holes provided. Included within
          the control is an intrinsically safe circuit (approved according to ATEX Directive 94/9/EC), to which the
          probe unit is connected. The probe and the circuit are intrinsically safe and are attached to a remote control
          unit.




          Figure 2.5 – Automatic closure device within the SPEL Tank


          The control unit should be connected to a suitable 220/240V AC supply and fused at 3 amps. This
          appliance must be earthed. Wiring from the control unit to the probe junction box in the separator chamber
          requires a 3-core screened, 0.75 mm core section cable and maximum cable length is 300 metres. A 5
          metre 3-core probe cable is normally fitted to the junction box and the probe. After all connections have
          been made, the cables must be secured by tightening each entry gland.


          Certificate of conformity
          The alarm device has been approved to be used in explosion-hazardous areas. The control unit and probe
          are approved according to ATEX Directive 94/9/EC. These approvals mean that the probes can be
          installed in Zone 0, which is continuously explosion-hazardous.




HEAD OFFICE                  POSTAL                          EMAIL                            ABN                          spel.com.au
100 Silverwater Road         PO BOX 7138                     [email protected]                83 151 832 629
Silverwater NSW 2128         Silverwater NSW 2128
Log in to download the original file

MCU14_0056 Response to SARA - Consulting Report.pdf · 24.7 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.