Council archive · source document
Geotech Report · OPW26/0094
Project No. PG-10899 Page | 10 November 2023 Ref: PG-10899, 2023-10-16, GR VER 1 DD Sunnyside CD Sunnyside Pty Ltd – Geotechnical Investigation - Proposed Residence, 30 Mossman Court, Noosa Heads 13.0 CONSTRUCTON MONITORING Construction vibrations could potentially cause settlement in the loose upper level sands, thereby damaging nearby structures founded in these strata. Prior to commencement of construction on site, it is recommended that a detailed dilapidation survey be undertaken to establish the condition of all existing adjacent structures. 13.1 Monitoring It is recommended that monitoring points should be established on the retention system to check for deflections during excavation. A suggested spacing of the monitoring points would be 10m along the walls. A regular monitoring program of these stations should be implemented. Monitoring must commence before any excavation to establish baseline readings. 13.2 Preconstruction Survey Prior to commencement of construction on site, it is recommended that a dilapidation survey be undertaken on the adjacent structures. This survey should include the following: • The extent of exiting damage (if any) • The general condition of the property, ie. Condition of all exposed columns and beams, partition walls and cladding etc. • Road, kerb and channel and footpath condition adjacent development site. 14.0 SITE MANAGEMENT To maintain the long term performance of the structure, good management of the soil conditions and the development is vital throughout the life of the development. The following are some specific comments with respect to site management: • The ground surface around the perimeter of the buildings should slope away from the structure and fall to the stormwater system. Water should not be allowed to pond adjacent to the buildings. • Founding soils should not be allowed to become saturated. • Service trenches under the buildings should be kept to a minimum. Saturation of the on-site material will result in an increase in settlement potential. • Footings should be poured immediately after compaction. If footings cannot be poured on the same day as compaction, a blinding layer of at least 50mm thickness is recommended.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Geotech Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.8 MB (small file)
- File type
No other editions are linked here.