07/2114 - MCU - Detached House [As Published] · 132007.2114
e
R.P. DESCRIPTION
Lot 14S.P. 143998
Parish of Tewantin
County of March
Area : 869m?
NOTES
Sewerage to discharge to existing sewer in
accordance with A.S. 3500.
Stabalized cut and fill batters to be a minimum of
1000mm away from footings and are to have 1 in 1
max. gradient. Grade finished surface level from
slab and footings.
Pasi
Nn af proposed building to be verified by
builder on site.
Location of existing services to be verified by
builder prior to construction.
STORMWATER DRAINAGE
DP1 - 100 downpipes to-stormwater pipes /
rainwater tanks as illustrated.
100mm min. cover. 1 in 100 mi
. fall.
DPS - Downpipe Spitter to lower roof.
Stormwater pipes shail be connected to
Kerb and Channel by use of a suitable PVC
adaptor which allows a min. of 75mm
(upright Kerb and Channel), 40mm (Layback
Kerb and Channel) of concrete above top of
adapter. The adaptor shall be cut to suit
the stope of the face of the kerb.
Kerb to be made good.
All stormwater drainage shall be in accordance with A.S.
3500.3.
All stormwater drainage shall be in accordance with N.S.C,
guidelines to minimise erosion and scouring. Stormwater flow
other than natural overland flow shall not be discharged onto
neighbouring property.
All stormwater drainage design is preliminary and shall be
confirmed by a licenced hydraulics designer.
PROPOSED RESIDENCE PROPOSED POOL Approx, tocation of
Approx. location confirm on site. Approx. & location confirm on existing Sewer MH.
‘ By Others. NV203Y01
Approx. location of LL 367
31.017m 88° 05' 10"
existing Sewer MH.
NU 203Y02
LL 383 4
ML. 1.74
tL. 206 _ Approx. location of existing sewer line.
“EMTE 3
on $.P. 106085 ~
Approx. location of
existing sewer house
connection point
HOB. 1.54 (10.)
Offset 0.46
LL 1.99
SL.348
T¥pe Stub
Approx. level site.
4109
181° 41' 49"
20.000m ., 358° 05' 10"
24.048m
™~
Approx. level site.
}
= B8.500m
268° 05' 10" |
27.500m 268° 05' 10"
Approximate tocation of Proposed
Colorbond Above Ground 216501
Rainwater tank.- 3.85m dia.
Overflow to kerb and channel.
PROPOSED DRIVEWAY
Approx. size & location confirm on site.
Cove Court
SITE PLAN
Scale 1: 200
GLIMATE.CODE.REQUIREMENTS.
Independent engergy assessor to confirm
adequacy of proposed construction. (if required.)
Provide insulation to B.C.A. code requirements.
Walls - R1.0, Roof - 2.5 or ta BERS
certification requirements.
GENERAL
Do not scale from these drawings, figured
dimensions take precedence at all times -
when in doubt consult the author.
Prior to commencing construction it is the
- ensure all boundary setbacks are strictly
adhered to.
- verify location and levels of all services on site.
- verify that floors and finished levels enable
connection to required services on site.
These drawings have been prepared for
building permit application only.
It is the builder's / proprietor's responsibility
to further interpret the design and
drawings to detail the project for construction.
TERMITES
Protection against subterranean termites to be
in accordance with AS 3660 Part 1. (protection
of buildings from subterranian termites).
Protection against subterranean termites to
apply to afl “primary building elements”.
The builder is to provide physical barriers to
the entry by subterranian termites by
construction of all slabs in accordance with
A.S. 2870.1 (Residential footing and slab
construction). and A.S. 3600 (Concrete
structures code). In addition all slab penetre
are to be protected using stainless steel mesh.
(Termimesh or equivatent fitted to manuf. spec.).
External perimeter barrier to be installed by
excavation trenches, treating the exposed
ing the trench with treated
material and protecting the trench with a
50mm thick concrete cover strip x 300mm
wide measured from the external wall of the
building. 2 durable notices shall be installed
in prominant locations stating method of
protection, date of installation, life expectancy
and scope and duration of future inspections.
Regular inspections of the building are to be
carried out to ensure the barrier has not
been bridged by termites.
Inspections are to be carried out as per notices.
nS
WINDOWS
Aluminium & Glazing in accordance with
A.S. 2047 - 1999 - Windows in Buildings.
To suit site design wind loading. Upgrade
at comers if required for jocal pressure effects.
AK BUILDING DESIGNL&
SCRA cis | MOLT A a [eR taeK
T. 07 5443 4200
F. 07 5443 3391
E. [email protected]
A. Suite 8/50 Aerodrome Rd Maroochydore
SmartChoice |A. & C. Pyziakos
A3
HOMES
CREATING ADVANCED LIFESTYLES
Lot 14 (No. 7) Cove Court
Noosaville
ABN 95 621 039 731
QBSA 1060583
P.O. Box 529 Cotton Tree Qld 4558
A PO, Box 1023 Buddina:
W www.smartchoicehor
Rev
DATE: 18/09/2007
DRAWING No:
07177A /01f,
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/2114 - MCU - Detached House [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.