 Plan of Development Provisions                                      Assessment
 • Details of proposed locations and dimensions of stormwater
 treatment systems possible to achieve the water quality
 objectives listed above.
 • Details of stormwater reuse strategies and detention devices
 to ensure the hydrologic regime is not altered from the current
 state.
 • Details of proposed management techniques to mitigate
 impacts from potential uncontrolled releases from the
 industrial uses and the sewerage pump station. Control
 measures shall be designed to prevent contaminants such as
 heavy metals/toxic chemicals leaving the site. These
 measures shall be located outside the vegetated buffer area.
 • Details of monitoring and reporting requirements to ensure
 achievement of the listed water quality objectives.
 The stormwater discharge from each lot site shall be designed
 such that there is no net increase in the rate of discharge as a
 result of the development for storm events up to 100 year ARI.
 Acoustic Treatments                                                 Some sections of the development site
 An Acoustic Report by an acoustic consultant to be submitted        include a transport noise corridor
 with each application to Council demonstrating that noise will      designated and gazetted by the state
 not exceed the following levels-:                                   under the Building Act. A portion of site
                                                                     specifically records     a    maximum
  Period          Noise Sensitive     Commercial Place               mandatory noise level Category 1
                  Place                                              (58dB(A) - <63dB(A) in SPP integrated
                  Adjusted Maximum Sound Pressure Level              mapping system below as a result.
                  Limit
  7am – 6pm       Background noise    Background noise
  (day)           level plus 5dB(A)   level plus 10dB(A)
  6pm – 10pm      Background noise    Background noise
  (evening)       level plus 5dB(A)   level plus 10dB(A)
  10pm-7am        Background noise    Background noise
  (night)         level plus 3dB(A)   level plus 8dB(A)

 This report shall identify measures to mitigate the potential
 noise impacts and meet the respective levels identified and
 include:
 • Buildings to be located adjacent the western or southern          Development can be conditioned to
 boundaries of lots (outside the vegetated buffers), with            comply with planning controls, building
 building to screen the noisier activities, such as loading docks,   treatment       and       plant/equipment
 open yards and other external activities from residents.            screening in accordance with the
 • For lots 1 and 2 continuous plant such as air conditioning        relevant acoustic requirements at the
 and refrigeration plant shall not be mounted on the building        building application stage for an
 roof and located in a manner that provides acoustic shielding       industrial use and in accordance with
 from the nearest residences to the west.                            QDC MP4.4. for the proposed caretaker
                                                                     accommodation premises.
 Landscaping                                                         Not Applicable
 Landscaping shall be undertaken in accordance with Council’s        A 10m buffer is not applicable for
 Landscaping Code nominated in The Noosa Plan 2006 (refer            Allotment 2 (site) and site does not have
 typical section of 10m buffer inset). A 10 metre wide               frontage to Holts Rd. Development does
 landscaping strip shall be provided on Allotments 1, 3 and 6        not propose removal of any mature
 for the full extent of the Holts Road frontage. All mature native   native vegetation.
 vegetation within the parking areas and outside the area
 subject to remediation, drainage or earthworks as a result of
 this application shall be preserved.
 Water Supply Requirements                                           Development is connected to the
 In addition to achieving connection to Council’s reticulated        existing reticulated water supply and
 water supply each allotment shall be serviced by its own water      can be conditioned to comply with
 storage and booster pump for fire-fighting as well as providing     Unitywater standards and requirements.
 a water supply for non-potable purposes. The storage shall be

                                                                                                                 21
Town Planning Report - 18 Taylor Court Cooroy QLD 4563

Log in to download the original (Town Planning Report 18 Taylor Court Cooroy Rev A (1).pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.