Noosa Plan 2020: Amendment 2
Part 6 Zones \ 6.5 Industry Zones Category \ 6.5.1 Low Impact Industry Zone Code




(b)   using a variety of external building materials for       Buildings visible from the street are articulated and use
      external walls where such walls are visible from         a mix of materials and appropriate design techniques
      the street;                                              to soften the bulk and scale of the building.
(c)   providing an interesting and varied site layout          AO15.3
      and roof design;                                         Buildings are finished in colours of muted
(d)   articulating the roof with a, pitched or skillion that   environmental tones. Broad expanses of a single
      complements the low rise character of the area           colour are avoided with walls broken up by natural
      and surrounding development: and                         tones or by design elements.
(e)   incorporate materials, finishes and colours that         Editor’s Note— Shades in the violet, blue, green and yellow-
      complement the natural environment.                      green side of the spectrum, as well as greys or browns,
                                                               should be appropriate with whites or bright colours restricted
                                                               to trimmings.
                                                               Hofmann Drive Business and Industry Precinct
                                                               AO15.4
                                                               A roof pitch of no less than 5 degrees with a minimum
                                                               600 millimetre eaves to 75% of the perimeter of the
                                                               building is provided.
                                                               Editor’s Note — a 450 millimetre eave with a 150 millimetre
                                                               gutter meets a 600 millimetre eave requirement.

Factory Street Business and Industry Precinct                  Factory Street Business and Industry Precinct
PO16                                                           AO16                                                             Not Applicable
Buildings and other structures present a high quality          Buildings are compatible with existing buildings
streetscape with building elements and forms that—             including Federation and Art Deco styles, without
(a) are consistent with the bulk and scale of                  necessarily mimicking such styles, through—
      buildings on nearby land;                                (a) suspended slab construction on columns/stumps
(b) contribute to and complement the rural heritage                  or posts;
      character through the use of Federation and Art          (b) features such as sunhoods to windows and wall
      Deco building styles;                                          openings and simple roof designs such as gabled
(c) present subtle changes in textures and materials                 or hipped;
      to break up building facades;                            (c) detailing and articulation for horizontal emphasis
(d) create pedestrian scale and visual interest;                     including awnings, parapet walls and balconies;
(e) integrate landscaping into the building design                   and
      and car parking areas;                                   (d) the main roof of the building has a pitch no less
(f)   is in keeping with the nearby development and                  than 5 degrees and a minimum of 600 millimetre
      the village; and                                               eaves to at least 75% of the perimeter of the
(g) screen services from the street.                                 building.
                                                               Editor’s Note — a 450 millimetre eave with a 150 millimetre
                                                               gutter meets a 600 millimetre eave requirement.


Print Date: 09/12/2025                                                                                                                           Page 9

Log in to download the original (Town Planning Report 18 Taylor Court Cooroy Rev A (1).pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.