Noosa Plan 2020: Amendment 2
Part 6 Zones \ 6.5 Industry Zones Category \ 6.5.1 Low Impact Industry Zone Code




Kin Kin Business and Industry Precinct                    Kin Kin Business and Industry Precinct
PO17                                                      AO17                                                          Not Applicable
Buildings and other structures present a high quality     With the exception of class 10 buildings or structures,
streetscape with building elements and forms that—        buildings—
(a) are consistent with the bulk and scale of             (a) have a floor plan predominantly comprising
      buildings on adjoining and nearby land;                   square or rectangular shapes;
(b) contribute to the historical village context;         (b) have a front elevation—
(c) create pedestrian scale and visual interest;                (i)   parallel to the front boundary;
(d) integrate landscaping into the building design              (ii) where the first floor presents balconies or
      and car parking areas;                                          awnings to the street;
(e) retain and enhance the Queensland vernacular                (iii) with recessed or framed windows and
      built form; and                                                 doorways;
(f)   retain and enhance the open streetscape and         (c) have sunhoods to windows and other openings;
      lack of formal boundaries between public and              and
      private lands.                                      (d) have a roof pitch no less than 12 degrees with a
                                                                minimum of 600 millimetre eaves to 75% of the
                                                                building.
                                                          Editor’s Note — a 450 millimetre eave with a 150 millimetre
                                                          gutter meets a 600 millimetre eave requirement.

Adaptability                                              No acceptable outcome provided
PO18                                                                                                                    Complies with PO18
Buildings are designed to provide for a range of                                                                        The proposal for low impact industry and ancillary
potential users by allowing for adaptable floor designs                                                                 transport depot with 54 Tenancies are variable and
and adequate floor to ceiling heights.                                                                                  adaptable ranging sizes from 147 m² to 352 m² GFA
                                                                                                                        to provide for a range of potential business within the
                                                                                                                        scope of the proposed uses. Once built the zone
                                                                                                                        allows other uses lawfully as accepted development
                                                                                                                        in existing buildings.
Mechanical plant, equipment and storage                   AO19.1
PO19                                                      Mechanical plant, refuse and recycling area, vents and        Complies with PO19
Mechanical plant and equipment (including air             exhausts are not visible from a street, public space or       Mechanical plant and service areas are screened
conditioning equipment) and storage areas are             adjoining residential use and is acoustically screen          and integrated into the building design.
designed and located to:                                  from adjoining sensitive land use.
(a) avoid adverse visual impacts when viewed from         AO19.2
     the street and adjoining properties; and             Mechanical plant and equipment are:
(b) visually integrate with the building design.          (a) located more than 2 metres from any property
                                                                boundary;


Print Date: 09/12/2025                                                                                                                                                 Page 10

Log in to download the original (Town Planning Report 18 Taylor Court Cooroy Rev A (1).pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.