Original source · versioned page text
Town Planning Report 18 Taylor Court Cooroy Rev A (1)
Attached to the e-mail Fw_ Email 3 of 3 - DA lodgement - 18 Taylor Ct Cooroy Lot 2SP197518 - Combined MCU_ OPW_ RAL under CTS (Pt 3).msg.
Noosa Plan 2020: Amendment 2
Part 8 Overlays \ 8.2 Overlay codes \ 8.2.9 Regional Infrastructure Overlay Code
Bulk water supply infrastructure - asset type Type of development Recommended separation distance minimum
Pipelines and channels (1) Buildings/Structures/Earthworks 20 metres from edge of pipe
Blasting(2,3) 200 metres from edge of pipe
Water treatment plants and water quality facilities Sensitive Land Use 250 metres from building footprint
Buildings/Structures/Earthworks 20 metres from building footprint
Blasting (2,3) 200 metres from building footprint
Reservoir facilities Buildings/Structures/Earthworks 20 metres from building footprint
Blasting (2,3) 200 metres from building footprint
Pump stations Sensitive Land Use 100 metres from building footprint
Buildings/Structures/Earthworks 20 metres from building footprint
Blasting 2,3) 200 metres from building footprint
Dam structures and weirs (4) Earthworks Dam/Weir Height(5) 0-5 meters 50 metres from the toe of the dam/weir
Earthworks Dam/Weir Height(5) 5-10 metres 100 metres from the toe of the dam/weir
Earthworks Dam/Weir Height(5) 10-15 metres 150 metres from the toe of the dam/weir
Earthworks Dam/Weir Height(5) 15-20 metres 200 metres from the toe of the dam/weir
Earthworks Dam/Weir Height(5) > 20 metres 500 metres from the toe of the dam/weir
Blasting (2,3) 500 metres from dam wall/earth embankment/weir
footprint
1 Channels are included in the pipelines and channels layer SPP IMS but are not differentiated from pipelines. Where an applicant identifies the bulk water supply
infrastructure is a channel rather than a pipe, applicants should contact the utility provider to discuss appropriate separation distances.
2 Refers to any type of development involving blasting <500 kg charge mass per delay, use of explosives, piling, and other vibratory/compaction machinery (over 20t
centrifugal force) during construction and/or operation. For blasting over 500 kg, applicants are to contact the asset owner as a greater separation zone may apply.
Print Date: 09/12/2025 Page 6