TABLE 3: RADIANT HEAT FLUX CALCULATIONS - PROPOSED LOT 1.
SPP Bushfire Asset Protection Zone Width Calculator
VARIABLE DESCRIPTION VARIABLE UNITS VALUE
Input Values
FIRE WEATHER SEVERITY FDI 47.00
VEGETATION HAZARD CLASS VHC 8.1 Wet eucalypt
- tall open forest
REMNANT STATUS - - Remnant
SLOPE TYPE (UPSLOPE OR DOWNSLOPE) ST - Downslope
EFFECTIVE SLOPE UNDER THE HAZARDOUS VEGETATION eSlope degrees 1.00
SLOPE BETWEEN SITE AND HAZARDOUS VEGETATION θ degrees 2.00
DISTANCE OF THE SITE FROM HAZARDOUS VEGETATION d m 32.00
Output Values
SURFACE FUEL LOAD - t/ha 28.00
NEAR SURFACE FUEL LOAD - t/ha 3.00
BARK FUEL LOAD - t/ha 2.00
ELEVATED FUEL LOAD - t/ha 2.00
TOTAL OVERALL FUEL LOAD W t/ha 35.00
TOTAL SURFACE FUEL LOAD w t/ha 31.00
POTENTIAL FIRE LINE INTENSITY I kW/m 33875
RADIANT HEAT FLUX q kW/m2 21.58
BUSHFIRE ATTACK LEVEL (AS 3959-2018) BAL - BAL 29
DISCLAIMER: Fire-line intensity and radiant heat calculations where effective slope exceeds 20 degrees (downslope) or 15 degrees
(upslope) may be unreliable. In these locations, specialist assessment is warranted.