                 Although the site does not contain bushfire prone areas, parts of proposed Lot 1 are the
                 potential impact buffer. As such, simple planning and management measures to mitigate
                 bushfire hazards are required for lot 1.

                 6.1.2    RADIANT HEAT FLUX

                 Radiant heat flux was calculated for the proposed building to support assessment
                 requirements set out in the Building Regulation 2006 (Qld) and Noosa Plan Bushfire hazard
                 overlay code. Any buildings should be re-assessed at the building application stage.

                 Radiant heat flux was calculated based on the distance between the closest edge of the
                 hazardous vegetation in accordance with Method 2 of AS 3959:2018 (View Factor Method),
                 utilising the input data described in Section 5 and the SPP Bushfire Asset Protection Zone
                 Width Calculator (Queensland Fire and Emergency Services 2019b).

                 The maximum view factor and radiant heat exposure was calculated i.e. the combination of
                 fuel, FFDI and site and effective slopes which maximised radiant heat flux. The model input
                 data and results of the calculations are indicated in Table 3. The measured separation
                 distances are indicated in Figure 7.

                 The outcomes of the calculations indicated that minimum separation distance between the
                 edge of hazardous vegetation on the northern side of Hoy Rd and the closest point on the
                 northern corner of proposed lot 1 is approximately 32m and the associated radiant heat flux is
                 21.58 kW/m2 (BAL 29).

                 Assessment results are preliminary only and subject to Council approval of the development
                 application. Changes to aspects of the development, including location and setbacks, may
                 result in changes to radiant heat flux calculations.




                                                                                                            19 | 31




Document Set ID: 23448646
Version: 1, Version Date: 13/01/2025
Log in to download the original file

REFERNCE DOCUMENTS - RAL25 0001.pdf · 28.3 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.