Council archive · source document
2009 KHA Original Report · REC14/0015
Attached to the e-mail REC14/0015 Report, Previous IR response, Plans and owner's consent Email 2 of 3.
KHA Development Managers May 2009 Specific Outcomes W Probable Solutions eam) O17 Essential public utilities are available and maintain their function during flood events up to a 1% AEP (1:100 year ARI) flood event. PSP24 — Effluent Disposal details requirements for the design and siting of effluent disposal systems where focated outside a sewerage service area. Compliance with PSP2¢ will be considered as part of Council's assessment of the plumbing and drainage application. $17.1 Components of the infrastructure that are likely to fail or may result in contamination are— a) located above the level of a 1% AEP (1:100 year ARI) flood event; or b) designed and constructed to exclude water inundation or infiltration and resist hydrostatic and hydrodynamic forces as a result of inundation. Can Comply All services can be located above 1:100 year ART Electricity supply infrastructure 018 Uses and works maintain a safe distance from electrical infrastructure including substations, overhead power lines, power poles and transformers. $18.1 Building footprints are situated clear of any power easements on-site; AND §18.2 Building footprints are not less than 50m from an existing fenced electricity substation. Complies No power easements located on-site Complies No electricity substation within 50m 44.190 Earthworks and stormwa ter management. 019 Stormwater run-off is managed so as not to cause any adverse impacts on the built or | natural environment including. _ - changes in quality, quantity or location of stormwater discharges. No solution provided Can Comply Stormwater will be undertaken in accordance with an approved 020 Filling or excavation only occurs where it does not adversely impact on— a) watercourses, drainage lines and wetlands; or b) vegetation on land identified on Biodiversity Overlay Maps OM1.1- OM9.1; or c) water levels on properties elsewhere. No prescribed solution. N/A No filling or excavation is proposed as part of this application. 14.191 Landscaping and_visual amenity. 021 Land development responds to the distinctive landscape character of the site by utilising the natural features of the site, which include— a) watercourses and drainage lines; b) significant trees; c) understorey vegetation; d) rock outcrops; and e) views. $21.1 The natural landform and landscape are not modified to accommadate the development. Complies No substantial modification of landform proposed as part of this application. 022 Native vegetation, including $22.1 Buffers of existing native N/A Town Planning Report Reconfiguration of a Lot Eumundi Noosa Road, Noosaville Page 22 of 31 Stormwater Management Plan. | |
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2009 KHA Original Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.