Skip to the record
The only place to find full transcripts.

Original source · versioned page text

Appendix C - Code Assessment

Attached to the e-mail Reconfigure a Lot (1 Lot into 4 Lots) - RAL17/0511.

of 23

Page text shows just the words. Original shows the document exactly as it was published.

Reconfiguring a Lot Code



                                                         S13.2 Community Title Development lots are
                                                         generally rectangular in shape and have a
                                                         maximum slope of—
                                                         a) 1 in 10 (10%); and
                                                         b) 1 in 20 (5%) when measured from the front
                                                         to the rear of the lot.
O14 For residential development the subdivision          S14.1 No Solution provided
design provides for the maximum practicable
number of lots with house site areas that—
a) maximise solar access to the north in winter;
b) minimise solar access to the east and west in
the summer;
c) maximise access to any prevailing summer
breezes; and
d) minimise exposure to prevailing winter winds.

14.189 Infrastructure
O15 Each lot is capable of being serviced by             S15.1 All lots are connected to power supply and    S15.1 – 16.1 – Complies
appropriate levels of—                                   telecommunications services;                        All lots will be connected to essential
a) water supply;                                         AND                                                 infrastructure.
b) reticulated sewerage;
c) stormwater drainage;
d) power supply; and
e) telecommunications;
O16 The design and provision of public services          S16.1 For lots in urban settlements—power supply    O16 – Specific Outcome
and utilities, including sewerage, water, electricity,   and communications infrastructure are provided      The development will be connected to the existing
street lighting and telecommunication services -         underground;                                        overhead power lines along church street and
a) meets the needs of users                              OR                                                  provided underground through the site.
b) ensures health, safety and convenience of the         S16.2 For lots elsewhere—power supply and
community;                                               communications infrastructure are provided
c) protects the natural environmental values of the      underground unless—                                 S16.2 – Not Applicable
site and surrounds, including visual amenity and         a) located in the Rural Zone or Rural Settlement
native vegetation;                                       Zone and where not in a Bushfire Hazard Area as
d) are cost effective over their life cycle;             defined on Overlay Maps OM1.4-OM9.4;
e) minimises adverse impacts to the environment          b) new low voltage lines can be strung from poles
Log in to download the original file

APPENDIX C - CODE ASSESSMENT.pdf · 314 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.