Council archive · source document
Appendix B Code Compliance Statements · MCU22/0038
Noosa Business Centre – Lot 22 Medihub Noosa Plan 2006 dated June 2018
Compliance
Specific Outcomes Probable Solutions Response
ü/û/NA
ii. increasing flooding, which adversely capacity toaccept any
affects the safety or use of any land additional loading;
upstream and downstream; and AND
iii. adversely affecting the flow of water S17.3
inany overland flow path. For Residential Uses—
a) where slab on ground
construction is used, filling
does not extend more than1m
beyond the building footprint
and access to car parking
areas, measuredfrom the
outer walls of the building ; or
b) the design consists of a
suspended floorconstruction;
AND
S17.4
Car parking and maneuvering areas
are constructed at a level that
permits the parking area to drain
from the site by gravitymeans,
without the need for mechanical
pumping;
AND
S17.5
Basements for residential uses have
flood immunity above the 1%AEP
defined flood event where
alternative means to mechanical
pumping are used to achieve such
immunity; or
S17.6
Basements for non-residential uses
have flood immunity above the
1%AEP defined flood event that may
be achieved bymeans of mechanical
pumping where the mechanical
Page | 9
See the original
The page text is free to read. Viewing or downloading an original file needs an account.