5.0 a) b) °) Job No. CE07/044 Where y = Sand Bulk Density © B = Pile Diameter D = Pile Depth . Kp = Coefficient of Passive Resistance = 5.0 (0-—3m) = 10.0 (> 3m) LONG TERM EFFECTS The Residence . The residence may be supported on stee! screw piles, for which an allowable base resistance may be taken as a minimum of 500 kPa in medium dense sand, provided that:- « The piles are hot dip galvanized to protect against corrosion ¢ The minimum pile depth is 4.5m below the present ground level A further requirement is that the residence is braced or stiffened in the east-west direction at least at floor level. It would be prudent also to provide lateral restraint at ground ‘evel to overcome a potential sand.slip or downslope creep. This matter is discussed further in (b) below. ' Slope Stability The concept of a garage structure at the foot of the slope removes most of the slope stability risk, but the site above the garage remains at a slope exceeding the natural . angle of repose for dry running sand. Over the residence footprint area, the dune slope is about 32 degrees, which could slump to 30 degrees under dry conditions and loss of vegetation. If this was the case, a break in the slope of 600-700mm could occur at the rear wall of the residence, with a rise of the same amount as slip debris at the rear garage wall. A low retaining structure should be considered at least at the line of the rear of the residence. Design Parameters Sand Density = 17 kNim* Active Pressure Coefficient Kg = 0.9 Passive Pressure Coefficient Ky = = 0.9 Sand anchors could be used for horizontal (and moment) restraint. Anchors should continue into the medium dense sand below a depth of 2.5 metres, where a pull out resistance of 300 kPa is available as end bearing or 15 kPa as allowable friction. Disposal of Wastewater and Stormwater It is understoad that the residential wastewater and stormwater are to be taken to discharge points in Park Road. This is acceptable provided that the same parameters are used to provide a safe slope, which have been given for the residence. It may be necessary to support the conduits on drilled piers aver the very steep slope area. 00979 Kidds & Co Designers MORRISON GEOTECHNIC
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
22441 DA - Response to Information Request [As Published]Related documentApplication case desk ↗
About this file
- File size
- 4.3 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.