Job No. 203E/194

rel
4.3. The Residence fh
The residence ners one on steel screw piles, for which an allowable base resistance
may be taken as 400kPa in medium dense sand, provided that~

i) The piles are hot dip galvanized to protect against corrosion.

ii) The minimum pie depth of 4.0m below the present ground level.
A further requirement Is that the residence is braced or stiffaned in the east-west direction at least

at floor level. It would be prudent also to provide lateral restraint at ground level to overcame a
potential sand slip or downslope creep, This matter Is discussed further in Section 5.

5.0 SLOPE STABILITY

The concept of a garage structure ai the foot of the slope ramoves most of the slope stability risk,
but the site above the garage remalns at a slope exceeding the natural angle of repose for dry
running sand, ,

Over the residence footprint area, the dune slope is about 32 degrees, which could slump to 30
degrees under dry conditions and loss of vegetation. If this was the case, a break in the slope of
600-700mm could occur at ihe rear wall of the residence, with a rise of the same amount as slip
debris at the rear garage wall. A {ow retaining structure should be considered at least at the line
of the rear of the residence,

Design Parameters

Sand:density : = 17kN/m®
Active pressure coefficientK, = 0.9
Passive pressure coefficlentK, = 0.9

Sand anchors could be used for horizontal (and moment) restraint. Anchors should continue into
the medium dense sand below a depth of 2.5 metres, where a pull out resistance of 300kPa Is
available as end bearing or 15kPa as allowable friction.

6.0 DISPOSAL OF WASTE WATER AND STORMWATER

tt is understoad that the residential waste water and stormwater are to be taken to discharge
points in Park Road. This is acceptable provided that the same parameters are used to provide a
safe slope, which have been given for the residence. It may be necessary to support the conduits
on drilled piers over the very steep slope area.

10096B Whaley Consulting Group (Robertson) : MORRISON GEOTECHNIC

Used in these records

About this file

File size
4.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

22441 DA - Response to Information Request [As Published].pdf · 4.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.