Skip to the record
NoosaWatch™: The source of truth.

Council archive · source document

001981A9.001

of 69

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Text sections not matched to the original PDF pages. See original document to check page numbers.

"        ,    MCU Application 11/12/2008                                                                                    Page    11

                                                                      the streetscape (the total width
                                                                      of garage doors is no more
                                                                      than 6m or 50% of the frontage
                                                                      width, whichever is the lesser,
                                                                      where the structure faces the
                                                                      street); or
                                                                      d} that are visible from, but do
                                                                      not face the street, include
                                                                      windows or other articulation
                                                                      and have a 6m landscaped
                                                                      buffer between the structure
                                                                      and the road frontage. and
                                                                      $36.2 Covered parking spaces
                                                                      located in the area between the
                                                                      swelling fagade and the road
                                                                      frontage do not comprise
                                                                      carports
                       Professional offices
                       037                                                                              ¥ NIA
 @                     Front fences and walls                          $38.1 Front fences or walls are | “Complies.
                       038 Front fences and walls are designed and | -
                       sited to-                                      a) not forward of the front plane
                       a) contribute to the attractiveness of the street; | of dwelling units; or
                       b) be compatible with the existing streetscape | b) no more than 900mm high;
                       character                                      or
                       c) relate to the architectural period of the | c) no more than 1.2m high and
                      building;                                        of open construction (ie at least
                       d) avoid interference with the movement of | 50% transparent),
                       stormwater;                                     OR
                       e) allow for casual surveillance from the street | $38.2 For   premises   with | “ N/A
                       or where premises adjoin part of the major | frontage     to the   major  road
                       road network, mitigate traffic noise            network front fences or walls
                       f) provide for planting in front of high solid | are no  more than    1.8m   in
                       fences and walls; and                           height and are articulated so
                       g) ensure planting between the front fence | that a minimum of 2m 2 of the
                       and   the   footpath  does   not  create  an | landscaped area is provided
                       impediment for pedestrians using the footpath | between   the fence   and  the
 @                                                                     front property boundary.

               6.3.   Residential Uses Code

                        Specific Outcomes                              Probable Solutions                  Compliance “/x
                        14.52 Effects of Use                                                                           no            a“
                        Electricity supply infrastructure
                        01 The development does not adversely          $1.1 No solution provided           Y The site is not near an
                        impact on existing or future electricity supply $2.1 Development for uses          electricity substation nor any
                        infrastructure;                                adjacent fo or within 50m of an     overhead transmission lines.
                        AND                                            existing electricity substation
                        02 All uses and works maintain an adequate     incorporates noise attenuation
                        safe distance from electrical infrastructure   measures to mitigate noise
                        including substations, overhead power lines,   impacts; and
                        power poles and transformers.                  $2.2 Buildings and structures
                                                                       {including swimming pools,
                                                                       outbuildings) are not constructed                                               f
                                                                       sheds, tennis courts and

                Material Change of Use                                                                        P. Conyers & K. O'Brien                    3
                34 Elanda Street, Sunshine Beach                                                                              Oct 2008

Used in these records

About this file

File size
3.4 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

001981A9.001.pdf · 3.4 MB (large file)