Skip to the record
Search everything, all in one place.

Council archive · source document

Appendix 5- Response to Planning Scheme Codes · MCU17/0027

Attached to the e-mail Engineering plans, Landscape Plan and Response to Code (Email 2 of 2) MCU17/0027 & OPW17/0119.

of 41

Text shows just the words. Original shows the document exactly as it was published.

(1) Existing Services

SPECIFIC OUTCOMES/ PROBALE SOLUTIONS                                          COMMENT

Setbacks and easements          S1.1 The footing of any structure or          Complies
O1 Development near a           building is located clear of the zone of
sewer,      water       main,   influence but no closer than 1.5m
stormwater drain, overland      (measured           horizontally)      from
flow path or associated         infrastructure including sewers, water
structure does not— a)          mains and stormwater structures; AND
adversely affect the function   S1.2 No building or structure overhangs       Complies
of the service; b) place an     the zone of influence; AND
additional load on the          S1.3 Finished surface levels maintain a       Complies
service; and c) unduly          minimum of 600mm of cover, but no
increase future maintenance     greater than 3m of cover to the
costs.                          underground infrastructure; AND
                                                                              Complies
                                S1.4 If the existing surface level is
                                altered, surface level services including
                                manholes and inspection points are
                                altered to match the new surface level;       Complies
                                AND S1.5 Alterations are constructed in
                                accordance       withPSP6      –Engineering
                                Design Standards — Water and
                                Sewerage and Section 4 of PSP5 –
                                Engineering Design Standards – Roads,
                                Drainage and Earthworks; OR
                                S1.6 Existing services are relocated and      Not Applicable
                                the design and construction of the
                                relocated services is in accordance with
                                PSP6 – Engineering Design Standards
                                — Water and Sewerage and Section 4 of
                                PSP5 – Engineering Design Standards –
                                Roads, Drainage and Earthworks
O2 Maintenance access is        S2.1 A registered easement in favour of       Complies
provided to all sewers,         Council is created over all underground       An existing sewerage easement in
water mains, stormwater         infrastructure located in private property;   favour of unity water exists onsite.
drains, overland flow paths
                                                                              Complies
and associated structures.       AND S2.2 The width of the easement is
                                the greater of 3m or the width of the zone    The sewerage easement is at
                                of influence;                                 least 3 metres wide.

                                AND S2.3 The easement is centred over         Complies
                                the centreline of the infrastructure.

Used in these records

About this file

File size
1.0 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Appendix 5- Response to Planning Scheme Codes.pdf · 1.0 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.