Appendix H Business Uses Code
Development Permit for Material Change of Use for Commercial Business Type 1 Office and Type 2 Medical, Ancillary
Dwelling Unit and Reconfiguration of a Lot (extension of access easement) at 36 and 40 Hofmann Drive Noosaville
described as Lots 6 &7 on SP264847


Divisions 3 Specific Outcomes and Probable Solutions for the Business Uses Code
Table 14-8

Specific Outcomes and Probable Solutions for the Shire Business Centre Zone
                 Column 1                                        Column 2                                              Column 3
             Specific Outcomes                     Probable Solutions (if code assessable)                            Compliance


 Table 14-8 For all Business Uses

 Electricity supply infrastructure
 O18 The development does not adversely            S18.1 No solution provided                      Complies
 impact on existing or future electricity supply
 infrastructure; AND

 O19 All uses and works maintain an adequate       S19.1 Development for uses adjacent to or       Complies
 safe distance from electrical infrastructure      within 50m of an existing electricity
 including substations, overhead powerlines,       substation incorporates noise attenuation
 power poles and transformers.                     measures to mitigate noise impacts; AND

                                                   S19.2 Buildings and structures (including       Complies
                                                   swimming pools, sheds, tennis courts or
                                                   outbuildings) are not constructed under
                                                   overhead electricity transmission lines, or
                                                   within electricity easements.

 Noise
 O20 Development is designed and sited to          No solution provided                            Complies – Building located in an industrial area
 avoid noise emissions that unreasonably                                                           with plant and service areas located internally to
 diminish the amenity of the area or                                                               building minimising any impacts on surrounding
 surrounding uses.                                                                                 area.

 Mechanical plant and equipment and
 storage areas
 O21 Mechanical plant and equipment                S21.1 Mechanical plant and equipment            Complies - plant and equipment located in
 (including air conditioning equipment) and        are—                                            basement of building.
 storage areas are designed and located to—        a) located more than 2m from any property
 a) avoid adverse visual impacts when viewed       boundary;
 from the street and adjoining properties; and     b) where located at ground level, screened
 b) visually integrate with the building design.   by fencing 1.5m in height or dense
                                                   vegetation of at least 1.5m in width
                                                   incorporating grouped trees and shrubs
                                                   with maximum separation distance of 1m
                                                   measured from the centre of the tree or
                                                   scrub; and
                                                   c) are visually integrated into the line and
                                                   plane of the building and roof design and
                                                   do not project beyond the height or width of
                                                   the building when viewed from the street
                                                   and adjoining properties; AND

                                                   S21.2 For Industrial business and Retail        Not applicable- no outside storage
                                                   business Type 3, materials stored outside
                                                   of a building do not exceed 4m in height or
                                                   half the height of the on-site buildings
                                                   whichever is the greater.
 Safety and security
 O22 All property boundaries are clearly           S22.1 Boundaries are identified by such         Complies - site well defined by landscaping and
 identifiable with public and private spaces       means as—                                       vehicular accessways.
 clearly defined.                                  a) fencing; or
                                                   b) changes in surface materials or levels; or
                                                   c) landscape treatments; AND

                                                   S22.2 Loading and storage areas are well        Complies – loading area located on ground floor
                                                   lit or can be locked after hours.               of building and able to secured.



                                                                                                                                        Page 2
Log in to download the original file

Appendix H - Business Uses Code.pdf · 63 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.