Original source · versioned page text
Planning Report
Specific Outcomes Probable solutions Proposal
entrance/exit;
AND
S11.2 All entrances/exits to Complies
buildings are lit and signed and Appropriate signage is able to be
signage includes hours of provided. This will be determined
operation; during detailed design.
AND
S11.3 Entrances/exits are located Complies
to provide a direct link to The entrance and exit of the
driveways and carparking areas; building are within close proximity
AND to driveways and carparking areas.
S11.4 Recessed doorways are Complies
avoided where the recess is of The proposed building does not
sufficient size to conceal a person. contain recessed doorways
Where recessed Appropriate lighting will be installed.
doorways are unavoidable,
measures are used to enhance
safety as follows—
a) good lighting is installed;
b) strategically placed mirrors are
installed;
c) angled approaches are
provided; and
d) gates which restrict access are
provided.
O12 Uses are arranged within S12.1 Windows and main Complies
buildings and on sites to enable entrances are positioned to allow Windows and entrances are located
external areas to be monitored. for casual surveillance. to look over pedestrian areas, car
parking and public spaces.
O13 Communal open space, S13.1 Communal open spaces, Complies
including congregation and seating including congregation and seating Areas of communal open space are
areas, is located where it can be areas, situated where they are in appropriately located and are able
monitored; the line of sight of windows, doors to be viewed from the building and
and/or balconies of buildings, or nearby streets.
can be seen from a street or other
public space.
O14 Buildings and structures are S14.1 Where buildings or Complies
designed to minimise opportunities structures are constructed in view The proposed buildings have been
for vandalism. of a public street or laneway— designed to be responsive to
a) the use of solid fences and vandalism and graffiti and include
blank walls which attract graffiti is appropriate architectural
avoided. Where solid blank treatments, landscaping, and
surfaces are unavoidable, building materials.
landscaping, creepers, murals,
vandal resistant paint, etc are
used;
b) toughened glass, security
screens and other measures (not
including opaque security shutters)
are used in windows which are
provided at ground level, to deter
break and enters;
c) hardy vandal proof materials
and antigraffiti paint are used in
the construction of buildings,
where appropriate.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.