Appendix D: Engineering Works Codes
EROSION AND SEDIMENT CONTROL CODE
PERFORMANCE CRITERIA ACCEPTABLE SOLUTIONS COMMENTS
b) localised erosion is avoided by directing flow from
downpipes over non-erosive areas.
Stormwater runoff S2.1 Diversion drains or bunds are designed and The Acceptable Solutions will be implemented as
O2 Stormwater is diverted around disturbed areas. constructed to drain upstream run-off around the practical to ensure that stormwater is diverted around
disturbed site; AND disturbed areas during the construction phase.
S2.2 Discharge from the diversion drains do not
cause run-off impacts to other properties; OR
S2.3 Alternative methods, as described in the
Institution of Engineers Australia (Queensland
Division) Soil Erosion and Sediment Control -
Guidelines for Queensland Construction Sites, are
used.
EXISTING SERVICES CODE
PERFORMANCE CRITERIA ACCEPTABLE SOLUTIONS COMMENTS
Setbacks and easements S1.1 The footing of any structure or building is The Acceptable Solutions will be implemented as
O1 Development near a sewer, water main, located clear of the zone of influence but no closer practical to ensure that the proposed development does
stormwater drain, overland flow path or associated than 1.5m (measured horizontally) from not—
structure does not— infrastructure including sewers, water mains and a) adversely affect the function of the service;
a) adversely affect the function of the service; stormwater structures; AND b) place an additional load on the service; and
b) place an additional load on the service; and S1.2 No building or structure overhangs the zone of c) unduly increase future maintenance costs.
c) unduly increase future maintenance costs. influence; AND
S1.3 Finished surface levels maintain a minimum of
600mm of cover, but no greater than 3m of cover to
the underground infrastructure; AND
S1.4 If the existing surface level is altered, surface
level services including manholes and inspection
points are altered to match the new surface level;
AND
S1.5 Alterations are constructed in accordance
withPSP6 –Engineering Design Standards — Water
CadCon Surveying & Town Planning
Page 9 of 24
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
MCU14/0045 & OPW14/0268: Appendix D - Engineering Works codesRelated documentApplication case desk ↗
About this file
- File size
- 193 KB (small file)
- File type
No other editions are linked here.