Original source · versioned page text
Residential Use Code
RESIDENTIAL USE CODE
For All Residential Uses
COLUMN 1 COLUMN 2 ASSESSMENT
SPECIFIC OUTCOMES PROBABLE SOLUTIONS (if code assessable)
Effects of Use
Electricity supply infrastructure
O1 S1.1 Complies with the Specific Outcome
The development does not adversely impact on No solution provided. The development will not affect electricity supply
existing or future electricity supply infrastructure; infrastructure.
AND
O2 S2.1 Complies with the Specific Outcome
All uses and works maintain an adequate safe Development for uses adjacent to or within 50m There is an existing electricity substation located
distance from electrical infrastructure including of an existing electricity substation incorporates on the site. The development application material
substations, overhead powerlines, power poles and noise attenuation measures to mitigate noise shows the substation being moved on site to be
transformers. impacts; located closer to the road and away from the
AND residential buildings. The acoustic impacts of the
substation will be limited.
S2.2 Complies with the Specific Outcome
Buildings and structures (including swimming pools, The development is not located within any
sheds, tennis courts or outbuildings) are not electricity easement.
constructed under overhead electricity
transmission lines, or within electricity easements;
AND
S2.3
A minimum separation distance is maintained from
the electricity transmission line to the closest
boundary of habitable buildings and child activity areas,
as follows
a) 20m for transmission lines up to 132kV;
b) 30m for transmission lines between 133kV and
275kV; and
c) 40m for transmission lines greater than 275kV.
Residential Use Code Page 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.