Original source · versioned page text
Appendix D - Previous Approval Dec Not
Attached to the e-mail MCU14/0083 Development Application Cover letter, Forms, Report.
REC12/0014.01
Any repair work which proposes to alter the alignment or level of existing services and
assets must first be referred to the relevant service authority for approval.
LANDSCAPE & ECOLOGY
Drainage
11. Provide adequate drainage to ensure no ponding of water or excessive overland water
flows are directed onto public access pathways.
Landscaping
12. All entry statements and landscaping batters must be located entirely within private
land and not within the public road reserve.
Vegetation
13. The northern portion of proposed lot 101 (approximately 400m2) must be rehabilitated
in accordance with the following requirements. These rehabilitation works must be
completed prior to the sealing of the plans:
(a) removal of all weeds species listed in the following standards and legislation:
(i) declared plants under the Land Protection (Pest and Stock Route
Management) Act 2002 and sub-ordinate Regulation 2003
(ii) Maroochy Pest Management Plan 2006-2010 pest species of
significance in Group 1, Group 2 and Group 6.
(b) Stabilisation of all exposed soils with local native species suitable for the local
soil conditions.
(c) Removal of spoil material and other foreign materials.
(d) Certification of weed removal by a suitably qualified person must be provided to
Council prior to the sealing of the plan of survey.
UNITYWATER
14. Reticulated water must be provided to each lot in the development. This must include:
(a) Ensuring that existing internal water pipes are wholly contained within the lot
they will serve
(b) An approved water meter for Lot 102 in accordance with Unitywater Standard
Drawings SCW 350,355 and 360.
(c) An approved 150mm diameter water service connection to Lot 102 in
accordance with Unitywater requirements.
(d) Water meters located on alternative boundaries to electrical pillars.
15. Reticulated sewerage must be provided to each lot in the development. This must
include:
(a) Ensuring existing sewer house drains are wholly contained within the Lot they
will serve.
(b) Extension of the existing sewer in Gateway Drive to the property boundary of
Lot 102, and provision of a sewer connection within Lot 102.
16. A 3.0 metre wide easement must be provided over all Unitywater sewers located in
private property. A 4.0 metre wide easement must be provided over Unitywater sewers
greater than 3.0 metres deep. Easements must be located centrally over the main.
17. Tree plantings must maintain a minimum horizontal clearance of 1.0 metre from
Unitywater water mains and 1.5 metres from Unitywater sewerage mains. Landscaping
plants within these clearances must be low growing when mature and suitable
Unitywater approved varieties.