Attached to the e-mail Updated SW management plan MCU14/0102.05.
2.4.2 HR Wallingford Testing – Oil & TPH
Tests were performed by HR Wallingford facility and at HR Wallingford UK with the device in flow mode, with
the following results. Test methodology was done to European Standard BS EN 858.1 Section 8.3. The results
are presented below.
Table 2. – Test results of SPEL Separators, HR Wallingford
Separator Model Range Average effluent oil
concentration* (mg/L)
NS4 <0.1
NS6 Puraceptor <0.1
NS30 0.5
NSB8 <0.1
NSB10 Stormceptor 0.7
NSB30 0.3
*Average of five samples with the requirement that none has an oil concentration higher than 10mg/L.
2.4.3 Australian Field Testing – Oil & TPH
Grab samples have been collected from a number of installations across Australia immediately after rainfall
events to compare the concentration of hydrocarbons in the inlet chamber to the outlet pipe. The results have
been collated for Woolworths Bombaderry, Woolworths Lakewood and Woolworths Warner and are presented
below.
Flow-weighted, Event Mean Concentration (EMC) field testing has commenced at a Freedom Fuels Station on
the Gold Coast and only 2 qualifying events have been recorded at present. This information will be released to
industry once further events have been received and reported on by the independent research organisation.
HEAD OFFICE POSTAL EMAIL ABN spel.com.au
100 Silverwater Road PO BOX 7138 [email protected] 83 151 832 629
Silverwater NSW 2128 Silverwater NSW 2128
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
F0002-AA007595-AAR-09-SMP.PDFRelated documentApplication case desk ↗
About this file
- File size
- 9.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.