Original source · versioned page text
Reference Document - Flood & Stormwater Management Plan 28_8_2025
Figure 2-4: 1% (2100) AEP Peak Water Surface Elevation Reporting Locations
It is noted that flood levels at 25 Pavilion St for the 1% (2100) AEP are unaffected by the proposal at 33
Pavilion St, with exception of the small area of afflux adjacent Lot 10. In this area, water surface elevation
has increased from 83.71m AHD to 83.8m AHD. However, this has no impact on Lot 10, 25 Pavilion St, as
the 1% AEP Peak Level adjacent the site is consistent with peak level of 85.11m AHD as per previous
modelling for 25 Pavilion St (report 21-0166SMP01-V1). The afflux is reasoned to be a small area of
instability within the model and is not predicted to be observable in practice.
23-0167SMP01-V4 | Stormwater Management Plan | 33 Pavilion Street, Pomona Page 28
Document Set ID: 24092538
Version: 1, Version Date: 02/09/2025
Preview the original
The page text is free to read. Previews and downloads of original files need an account.
Log in to previewSearchable page text hides email addresses. Original files are unchanged and may show email addresses.