ORDINARY MEETING AGENDA 17 AUGUST 2017
d. Retention of existing street trees (with consideration to be given to the
viability of retaining the tree(s) close to the new vehicle crossover(s)in the
context of the likely construction disturbance).
e. Replacement for any street tree proposed to be removed with advanced
ex-ground street tree(s).
f. Screening vegetation along the western boundary and front setback.
g. The all-weather pedestrian surface treatment to the 3m wide access
easement at the north of the site.
h. Clearly detail any proposed front fencing.
22. All landscape works must be maintained generally in accordance with the
approved design for the life of the development.
External Works
23. Roadworks must be provided within the proposed 3.0m wide “Public
Thoroughfare” easement adjacent to the northern boundary of the site,
extending from the eastern side of the bin area to remaining length of the
northern boundary. The works must be undertaken in accordance with an
Operational Works approval and must include in particular:
a. 2.0m wide concrete pavement along full length of the easement. The
formation must be designed to cater for the potential future use by
vehicles and be in accordance with Council’s Planning Scheme Policy 5 –
Engineering Design Standards – Roads, Drainage and Earthworks.
b. Landscaping works to provide a suitable visual screening buffer between
the building and the easement with a minimum garden bed width of
800mm.
c. Pram ramps where required.
d. Any necessary alteration and reinstatement works beyond the boundary
of the site to connect and match existing public carparks or pathways
pavements.
Site Access and Driveways
24. A sealed access driveway must be provided from Doonella Street to all parking
and maneuvering areas of the development generally in accordance with the
approved plans (16416–SD02 dated 02/05/2017 by Archicology). The works
must be undertaken in accordance with an Operational Works approval and
must include in particular:
a. A driveway crossover 4.0m wide with grades generally in accordance with
IPWEAQ standard drawings SEQ R-049 and R-050 with line marking and
modified driveway tapers at 45 degree at the kerb line to encourage left-in
and left-out from the site (refer to Parking & Traffic Impact Assessment
Report – Addendum 1, Reference 210442017TIA-Add, dated 21 April
2017 by Greys Australia Pty Ltd).
b. Signage and linemarking in accordance with Manual of Uniform Traffic
Control Devices (MUTCD) installed within the site to indicate left-out only
traffic.
c. Grades to allow for a compliant concrete pathway along the frontage.
d. Any landscaping, fences and fixtures near the access entry point must
comply with AS 2890.1 requirements for sight visibility for pedestrians and
cyclists at driveways.
Page 23 of 89
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.