ORDINARY MEETING AGENDA                                                        17 AUGUST 2017


  The bin store area is moved into the new service yard
  The gas bottles are relocated from ground floor to basement area adjacent to the existing
   transformer.
 The wall adjacent to the fire hydrant booster is extended to comply with fire regulations
   (located at BA car park entry).
 The larger ‘pop up’ roof above the gaming extension is reduced in length to minimise invasive
   construction works above the existing building and enable the infill roof area to better
   integrate with existing pitched roof form.
 The transition from the lower roof to the ‘pop up’ roof occurs at a slightly higher position (to
   align with the adjoining plant deck), but the overall roof height is unchanged.
 The plant deck is correctly located in drawing cross sections to match with the floor plans.
 The wall around the plant deck is revised to fibre cement weatherboard cladding to be more
   consistent with the overall building aesthetic.
 A small panel of weatherboard wall section is removed in the south elevation of the carpark to
   allow improved carpark ventilation.
 The ground floor car park balustrade is shown at the correct level (1300mm high) as required
   for barriers in elevated carparks.
 The windows in the children’s lounge are changed to full height.
 Shared access path to lift in basement omitted
 Omitted three disabled car parking bays in existing basement with two spaces being added to
   new basement area
 Wall around plant deck extended to top of plant
 Replaced weatherboard wall section with aluminium battens in south elevation (to create
   bigger opening).
The application also proposes to change conditions 2, 9 and 12 as follows:
  Amend conditions 2 and 9 to reflect the new set of plans.
  Delete condition 12 which relates to the requirement for certain aluminium materials to be
   replaced by timber materials so that the development is consistent with Tewantin’s heritage
   character.
The following images detail the approved and proposed elevations




                                                                      Figure 1: Approved elevations



                                                                                   Page 57 of 89
Log in to download the original file

2017-08-17 Ordinary Meeting Agenda(PDF, 9MB).pdf · 9.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.