Original source · versioned page text
Applicant's Response to Council's FA
The southern property boundary carpark is not functional. Insufficient room has been provided for a driver to exit the vehicle. Insufficient detail has been provided demonstrating how vehicles enter and exit the carpark, noting that all vehicles must exit in a forward gear. Information Required 1. Provide amended Vehicle Turn Paths plans. The amended plans must be prepared by a suitably qualified person (RPEQ) and include, but not be limited to: a) Demonstrate how B99 and B85 vehicles will enter the site in a forward gear, manoeuvre on-site in a reasonable number of movements, and exit the site in a forward gear; b) Demonstrate how B99 and B85 vehicles will access the southern-most carpark; and c) All start/end points must be realistic and allow for sufficient clearances. Applicant's Response Please refer to the Traffic Engineering Review of Vehicle Accessibility (Attachment 1) conducted by BMC Traffic, which highlights the following key aspects: 1. The site offers forward in/forward out access, ensuring access to all car parking bays. 2. There is provision for parking both B99 and B85 vehicles within the undercover carport. 3. Reverse-in parking is available for both undercover parking spaces, allowing for a single forward exit maneuver from the site. 4. A dedicated aisle for parking one vehicle, with the following considerations: 4 PO Box 1818 07 S474 3873 (5 Noosa Heads [email protected] QLD 4567 rgstrategic.com.au
See the original
The page text is free to read. Viewing or downloading an original file needs an account.