MCU21-0134 - Approved Bushfire Management Plan
Plans and drawings
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnBushfire Management Plan v1 NCES REF: J000953 Lot 189 on MCH1261 – 64 Reserve St, Pomona Plate 8 – VHC 9.1 to the west (onsite) - 1-degree slope – 30m flame width (Source: FPA Australia) The bushfire model output results identify that the VHC 8.1 produces a fireline intensity of 33,875 kW/m irrespective of flame width and therefore represents a High Potential Bushfire Intensity class under the SPP (i.e., 20,000 – 39,999 kW/m). The VHC 9.1 produces a fireline intensity of 15,866 kW/m irrespective of flame width and therefore represents a Medium Potential Bushfire Intensity class under the SPP (i.e., 4,000 – 19,999 kW/m). © 2021 11