Continued:
5. Excavation of the basement to the underside of capping beam level.
6. Bracing installed to support the structure during construction.
7. Excavation to be continued in approximately 2-3m increments to allow steel and shotcrete
to be installed.
8. Repeat methodology until underside of bottom basement slab RL is reached.
NOTE:
This methodology does not incorporate any anchors within the site or encroaching into neighboring
properties. It will not have any adverse effect on adjoining infrastructure, buildings or vegetation.