Skip to the record
The definitive source for everything Noosa Council.

Original source · versioned page text

2020-07-16 SM Agenda - Item 1 - Attachment 5 - Final Noosa Plan 2020 Part 8-10 Schedules & Appendix

of 389

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Very large file: it may take a few minutes

The original of this document is very large (19.9 MB). Opening the original or downloading it may take a few minutes. Please be patient and don't click again. The page text is quick to read. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Plans and drawings

This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).

Log in to see the plans as drawn
  Table 9.4.4.3 Criteria for assessable development
 Table 9.4.4.3 Criteria for assessment
  Performance outcomes                                              Acceptable Outcomes
  Assessable development

  Installation of hydrant
  PO1                                                               AO1.1
  Fire hydrants are installed and located to enable QFES            Fire hydrant placement and technical requirements for
  vehicles to access water safely, effectively and efficiently.     residential streets and common access ways within common
                                                                    private title are in accordance with:
                                                                    (a)   Australian Standard (AS) 2419.1 – 2005 Fire hydrant
                                                                          installations; and
                                                                    (b)   QFES: Fire Hydrant and vehicle access guidelines for
                                                                          residential, commercial and industrial lots.


                                                                    AO1.2
                                                                    Fire hydrant placement and technical requirements for
                                                                    commercial and industrial streets and access ways within
                                                                    streets serving commercial properties, such as factories,
                                                                    warehouses and offices, are in accordance with:
                                                                    (a)   Australian Standard (AS) 2419.1 – 2005 Fire hydrant
                                                                          installations; and
                                                                    (b)   QFES: Fire Hydrant and vehicle access guidelines for
                                                                          residential, commercial and industrial lots.


                                                                    Editor’s Note— Design and technical requirements for
                                                                    infrastructure from third party providers are to be in addition to,
                                                                    and integrated where possible, into the overall design, built
                                                                    form and landscaping requirements for the development.
  Road technical standards
  PO2                                                              No acceptable outcome provided.
  Road widths and construction within the development are
  adequate for QFES vehicles to gain access to a safe working area Editor’s Note—Roads should be designed and constructed in
  close to buildings and near water supplies whether or not on­    accordance with Road Planning and Design manual­ 2nd edition.
  street parking spaces are occupied.


 9.4.5             Landscaping Code

 9.4.5.1           Application
 (1)    This code applies to assessable development identified as requiring assessment against the Landscape code by the tables of
        assessment in Part 5 (Tables of Assessment).
 (2)    All provisions in this code are assessment benchmarks for applicable assessable development.

 9.4.5.2           Purpose and Overall Outcomes
 (1)    The purpose of the Landscaping code is to ensure development:
        (a)   incorporates landscapes that are consistent with and protect and enhance the amenity and distinct vegetated
              character of Noosa Shire; and
        (b)   creates quality places and spaces.
 (2)    The overall outcomes sought for the Landscaping code are:


NOOSA PLAN 2020                                                                                                             Page 95 of 150
Log in to download the original file

2020-07-16 SM Agenda - Item 1 - Attachment 5 - Final Noosa Plan 2020 Part 8-10 Schedules & Appendix(PDF, 19MB).pdf · 19.9 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.