Log in to see the plans as drawn (a) Underground infrastructure is accessible for maintenance purposes.
(b) Existing services are identified and methods of protection and access are implemented in the design of the development.
Table 9.4.3.3 Criteria for assessment
Setbacks, easements and maintenance Table 9.4.3.3 Criteria for assessment (part)
Performance outcomes Acceptable Outcomes
Assessable development
PO1 No acceptable outcome provided
Development near a stormwater drain, overland flow path or
associated structure does not—
(a) adversely affect the function of the service;
(b) place an additional load on the service; and
(c) unduly increase future maintenance costs.
PO2 AO2.1
Maintenance access is provided to all stormwater drains, overland For trunk infrastructure, a registered easement in favour of Council
flow paths and associated structures. is created over all underground infrastructure located in private
property.
AO2.2
The width of the easement required is in accordance with
Council’s Planning Scheme Policy PSP6 Engineering Design
Standards – Roads, drainage and earthworks.
AO2.3
The easement is centred over the centreline of the infrastructure.
9.4.4 Fire services for common private title code
9.4.4.1 Application
(1) This code applies to assessable development identified as requiring assessment against the Fire Services code by the tables of
assessment in Part 5 (Tables of Assessment)where the development:
(a) is for a material change of use or reconfiguring a lot for the purpose of residential, commercial or industrial development
where part of the development or any building is more than 90 metres from the nearest located fire hydrant; or
(b) for attached and detached buildings, not covered in other legislation or planning provisions mandating fire hydrants; and
(c) the proposed development will include streets and common access ways within a common private title in areas serviced
by reticulated water.
(2) All provisions in this code are assessment benchmarks for applicable assessable development.
9.4.4.2 Purpose and overall outcomes
(1) The purpose of the Fire services code is to ensure development in urban areas accessed by common private title have
appropriate fire hydrant infrastructure and unimpeded access for Queensland Fire and Emergency Service (QFES) vehicles for the
protection of people, property and the environment from fire and chemical incidents.
(2) The overall outcomes sought for the Fire services code are:
(a) Development provides for suitable fire hydrant infrastructure which is located to safely, efficiently and effectively access
water supply and is integrated into the overall design of the development.
(b) Development provides for unimpeded access for QFES vehicles to fire hydrant infrastructure.