Log in to see the plans as drawn Performance Outcomes Acceptable Outcomes
(c) not located within a riparian buffer area mapped on a
Biodiversity, Waterways and Wetlands Overlay Map; and
(d) setback 400 metres minimum from the full supply level of
Lake Macdonald.
Editor’s Note—The Plumbing and Drainage Act 2003 sets out
requirements for onsite effluent treatment and disposal. The
Queensland Plumbing and Wastewater Code and associated
guidelines are used to confirm the suitability of each site to
accommodate an onsite sewerage facility; or where a centrally
located group collection treatment system is proposed,
confirmation as to the suitability of the designated site to
accommodate the onsite sewerage facility. Additionally, where the
combined total peak design capacity of effluent treatment is less
than 21 equivalent persons, the design of the system achieves a
low to medium risk classification in accordance with Seqwater’s
Land Use Risk Tool for onsite sewerage facilities.
9.4.9 Waterways Works Code
9.4.9.1 Application
(1) This code applies to assessable development identified as requiring assessment against the Waterways works code by the
tables of assessment in Part 5 (Tables of assessment).
(2) All provisions in this code are assessment benchmarks for applicable assessable development
Editor's Note—This code must be read in conjunction with the ‘Code for assessable development that is prescribed tidal work’ contained in Schedule
3 of the Coastal Protection and Management Regulation 2017.
9.4.9.2 Purpose and overall outcomes
(1) The purpose of the Waterways works code is to ensure the suitability of development within tidal areas and the waterways of the
Noosa Waters Estate.
(2) The overall outcomes sought for of the Waterways works code are:
(a) Development is compatible with the character and amenity of its surrounding area.
(b) Development ensures there is no increase to the scale and intensity of commercial operations on the Noosa River and
additional commercial leases are avoided.
(c) Development is designed and constructed in a way to ensure it is structurally sound.
(d) Development is safe for use.
(e) Development does not adversely affect—
(i) the amenity of the surrounding area including by noise, lighting, odour and air pollutants;
(ii) existing public access to any foreshore areas or tidal waters;
(iii) safety and navigation of any waterways;
(iv) natural values of waterways, including water quality and bed and bank habitat;
(v) the flood storage area of waterways of the Noosa Waters Estate; and
(vi) the structural integrity, operation or maintenance of any existing structure.
Table 9.4.9.3 Criteria for assessment
Landing Table 9.4.9.3 Criteria for assessment (part)
Performance Outcomes Acceptable Outcomes
Landing prescribed tidal works outside Noosa Waters Estate