Log in to see the plans as drawn Performance Outcomes Acceptable Outcomes
(a) a maximum of 2 jetties per multiple dwelling;
(b) jetties are shared between unit owners;
(c) a minimum of 20 metres separation is provided between
each jetty;
(d) the jetty is setback a minimum of 3 metres from the
prolongation of boundaries; and
(e) jetty heads and pontoons are not constructed (Refer Figure
9.4.9.3F).
AO19.7
For multiple dwellings where each unit has its own individual
canal frontage—
(a) a joint application with the adjoining owner is made; and
(b) jetties are constructed as follows—
(i) the jetty is shared between two unit owners;
(ii) the jetty straddles the common boundary of the two
units;
(iii) jetty heads and pontoons are not constructed; and
(iv) fencing between the two properties is setback a
minimum 1 metre from the revetment wall to allow
for efficient access to the jetty by both owners (Refer
Figure 9.4.9.3G).
Editor’s Note—Council is unlikely to support a jetty application for
the exclusive use of one unit owner.
AO19.8
Walkways serving jetties have at least one rigid handrail fitted and
the walkway is a minimum width of 750 millimetres and a
maximum width of 1.5 metres where—
(a) the walking surface of the jetty is constructed level with the
top of the revetment wall;
(b) water reticulation systems are fitted with a mechanical
backflow prevention device; and
(c) electrical reticulation systems carrying electricity in excess
of 24 volts are not to extend beyond the revetment wall.
AO19.9
Any lowerlevel platform, or siding, along the jetty walkway has a
maximum width of 500 millimetres and does not exceed 2m² and
does not interfere with the prolongation of boundaries as
indicated by Acceptable outcomes AO15.1, AO15.2 & AO15.3.
PO20
Pontoons and boat ramps are not constructed within the Noosa No acceptable outcome provided
Waters Estate waterways.
Boat lifting devices Table 9.4.9.3 Criteria for assessment (part)
Performance Outcomes Acceptable Outcomes
Boat lifting devices within Noosa Waters Estate waterways
PO21 AO21.1
Boat lifting devices are only constructed in the absence of a boat Boat lifting devices are only located in conjunction with an
ramp and are designed and located to— approved jetty where—
NOOSA PLAN 2020 Page 126 of 150
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalVery large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.