PO14 AO14.1
Driveways and crossovers are located so they do not impede the Only one driveway and crossover is provided.
safe and efficient use of the road network.
AO14.2
Where the premises has frontage to more than one formed and
sealed road and the roads have differing orders in the Road
Hierarchy, the driveway and crossover is provided on the frontage
with the lower order.
AO14.3
For corner lots, driveways and crossovers are located in
accordance with Council's standard drawings.
AO14.4
If in the Rural zone or Rural Residential zone, the driveway and
crossover is located to provide minimum safe sight distances in
accordance with Austroads.
Editor's Note An operational works application is required for a
second driveway.
Bushfire Hazard Management
PO15 AO15
Where located in a Bushfire Hazard Area as shown on the Within a bushfire hazard area where there is no reticulated water
Bushfire Hazard Overlay Map in Schedule 2 and not in a water supply, the premises has:
service area, an adequate, reliable, safely located and freely (a) an accessible dam, swimming pool or water tank available
accessible water supply is provided for fire fighting purposes, for firefighting purposes with an onsite water volume of not
which is in addition to day to day water supply. less than 5,000 litres; and
(b) a water supply outlet pipe 50 millimetres in diameter and
fitted with a standard fire brigade fitting connected to the
water supply (other than where the water supply is in a
swimming pool or dam).
Editor’s Note — Water supply capacity for firefighting purposes is
in addition to water supply capacity for household use.
Flood Hazards
PO16 AO16.1
Development is designed and sited to ensure risk to people and Where the development is located in the Flood Hazard Area as
property from flooding is avoided or minimised. shown on Flood Hazard Overlay Map in Schedule 2,
the finished floor level of habitable rooms is at least 300
millimetres above the Defined flood event (DFE).
OR
AO16.2
Where the DFE has not been modelled for the area, the finished
floor level of habitable rooms is at least 500 millimetres
above the highest recorded flood.
Editor's Note—The QDC mandatory provisions MP3.5 also apply
to the construction of buildings in flood hazard areas.
PO17
Underground car parking areas are designed to drain and No acceptable outcome provided
function safely during a flood event and power failure.
Editor's note—Basements should have flood immunity above the
1%AEP defined flood event with alternative means to mechanical