17.0 WATER SENSITIVE DESIGN CODE
COLUMN 1 COLUMN 2 ASSESSMENT
SPECIFIC OUTCOMES PROBABLE SOLUTIONS (if code assessable)
Water reuse
O1 S1.1 Complies with specific outcome.
Development uses a combination of detention and No solution provided. Development will collect roofwater run-off from
retention systems to capture run-off from areas on the villa units in above ground storage tanks for
the site; reuse in garden watering. The site is within the
AND Noosa Council designated area for rainwater tanks.
In accordance with the Council policy the villas
will be provided with a 3000 litre rainwater tank to
be installed in accordance with Part 25 of the
Queensland Development Code. Rainfall
harvesting for reuse will be from the villas and not
provided on other buildings.
O2 S2.1 Complies with specific outcome.
Water storage devices must have sufficient capacity No solution provided. Water storage devices are sized to comply with
having regard to local rainfall pattern and surface; Council policy which requires a 3000 litre rainwater
AND tank.
O3 S3.1 Can comply.
Captured water is utilised for all non-potable uses Captured water is plumbed to be available for all At this stage, it is proposed that all captured water
on site; external uses including gardening, irrigation, ponds, is to be reused for landscape irrigation.
AND filling swimming pools and outdoor cleaning, as
well as all ground floor toilet cisterns and washing However, if the quality of captured water can be
machine cold taps; demonstrated to be suitable for household
AND purposes, a dual system could be installed in units
and resort central facilities.
S3.2
Where the captured water is used for toilet flushing
and/or laundry use, an automatic or manual
interchange device that allows alternate use of
captured water or the reticulated water supply is
installed to ensure that there is a continual supply
of water for sanitary flushing and laundry use.
Volume II: Code Responses
Viridian Noosa Project
Viridian Stage 3
Water Sensitive Design Code 11 April 2006 Page 132
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Volume 2 - Code ResponsesRelated documentApplication case desk ↗
About this file
- File size
- 5.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.