                     COLUMN 1                                                COLUMN 2                                               ASSESSMENT
               SPECIAL OUTCOMES                           PROBABLE SOLUTIONS (if code assessable)
   standards; and                                       Constructed data submitted in accordance with              with the requirements of the existing site
b) to minimise adverse environmental impacts            Section 7 of PSP6 Engineering Design Standards             Development Approval.
                                                        Water and Sewerage;
                                                        AND

                                                        S9.2                                                       No additional sewage reticulation infrastructure is
                                                        Erosion and sediment control measures are                  required.
                                                        designed and implemented in accordance with the
                                                        Institution of Engineers Australia (Queensland Division)
                                                        Soil Erosion and Sediment Control - Guidelines for
                                                        Queensland Construction Sites.
O10                                                     S10.1                                                      Not applicable.
Sewerage reticulation infrastructure is proven          No solution provided.                                      No additional sewage reticulation infrastructure is
to be suitable for its use prior to Council accepting                                                              required.
the dedicated asset.
O11                                                     S11.1                                                      Not applicable.
Sewerage reticulation infrastructure is provided        No solution provided.                                      No additional sewage reticulation infrastructure is
with all supporting technical documentation.                                                                       required.
O12                                                     S12.1                                                      Not applicable.
Where buildings or other structures are developed       The footing of any structure or building is located        No buildings are being developed in close
adjacent to Council s sewerage reticulation             clear of the zone of influence but no closer than 1.5m     proximity to Council sewerage reticulation
infrastructure, satisfactory provision is made to       (measured horizontally) from infrastructure                infrastructure.
protect the infrastructure from physical damage         including sewers, water mains and stormwater
and to allow ongoing maintenance by Council.            structures;
                                                        AND

                                                        S12.2
                                                        A registered easement in favour of Council is              No easements are required.
                                                        created over all underground infrastructure located
                                                        in private property;
                                                        AND

                                                                                                                                                     Volume II: Code Responses

                                                                                                                                                     Viridian Noosa Project
                                                                                                                                                     Viridian Stage 3

Water Supply and Sewerage Reticulation Code                                                                                                          11 April 2006     Page 141

Used in these records

About this file

File size
5.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Volume 2 - Code Responses.pdf · 5.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.