STATEMENT OF ENVIRONMENTAL EFFECTS Page 8 of 13 Lake Macdonald water supply. Electricity supply infrastructure O4 Uses and works maintain an adequate safe distance from electrical infrastructure including substations, overhead powerlines, power poles and transformers. 84.1 Buildings and structures (including swimming pools, sheds, tennis courts or outbuildings) are not constructed under overhead electricity transmission lines, or within electricity easements. The Site is not affected by Electricity infrastructure : Landslide hazard areas OS Detached houses, Ancillary dwelling units and associated uses are sited or constructed to maintain the safety of people and property from the risk of landslide. 85.1 fon land identified as a Landslide Hazard Area on Overlay Maps OM1.3-9.3, the use does not- 4) involve the removal of vegetation other than grass from use areas: or b) involve excavating or filling of more than 50m3 of material (other than placement of topsoil not exceeding 100mm in depth: or c) involve cut or fill with a vertical depth of more than 1.5m relative to ground level; or d) redirect or impede water flows in an existing watercourse or stormwater drain; or e) involve construction of an on-site effluent disposal system; or 85.2 A site specific geo-technical report prepared by a registered professional engineer either-- a) certifies that the site is not at risk from landslide emanating from the site or from other land; or b) identifies methods of stabilising all buildings, accessways and use areas; AND $5.3 If the geo-technical report identifies methods of stabilising buildings, accessways and use areas, those methods are implemented. The Site is affected by Landslide hazard, Iti envisage that suitable method of stabilise the land will be prepared by a qualified structural engineer when the geotechnical report is available and will be submitted at the building certificate stage. The proposed residential development_also try to mitigate the affect to the area by inyolycs minimal earthworks, In regards to the issues of soil and water treatment, please refer to Hydraulic Documents for detail. [14.66 Built for 1 rr | Height 06 Buildings and other structures— a) are low rise and present a building height consistent with structures on adjoining and surrounding land; b) have a maximum building height of-i) Visitor Mixed Use Zone- 3 storeys; or ii) if in the Noosa Heads Locality Attached Housing Zone— + Lot 4 on SP100064 in Serenity Close Noosa Heads— 4 storeys * Otherwise— 3 storeys iii) if in the Noosaville Locality and the Attached Housing Zone with frontage to the following streets: - Russell St, William St and Howard St, or Weyba Rd, James St and Albert St north of their intersections The proposed development complies with this requirement by maintaining: Two Storeys — Below maximum height of 8m at any point of the cross sections Single storey & part second storey with garage in part lower level 23 peck seah street #03-116 | 118 singapore 079313 ? co. registration no. 2003033482 tel: +65 6327 6210 7 fax: +65 6327 8201 ? email [email protected] web: www.arplusd.net
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1541 - MCU - Detached House [As Published]Related documentApplication case desk ↗
About this file
- File size
- 7.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.