Original source · versioned page text
Kenlynn Castaways Beach BMP
Attached to the e-mail Request for Negotiated Decision Notice REC16/0015.
This Plan serves to protect life and property from bushfire without
depending on emergency services for protection.
(3) directly, indirectly and cumulatively avoids The development reduces the nature of the existing hazard, and landscaping
an increase in the severity of the natural on the site is designed to moderate the exposure of buildings, which will also
hazard and the potential for damage on the be constructed in accordance with AS3959-2009. The potential for damage
to other properties will not be increased as a consequence of the proposed
site or to other properties, and
development.
(4) avoids risks to public safety and the Hazardous materials are not stored in quantities or locations on the site
environment from the location of hazardous which would pose a risk to the public or the environment.
materials and the release of these materials
Natural processes and protective functions of landforms and adjacent
as a result of a natural hazard, and
vegetation are unaffected by the development or bushfire mitigation
maintains or enhances natural processes measures required by this Plan.
and the protective function of landforms
and vegetation that can mitigate risks
associated with the natural hazard
(5) maintains or enhances natural processes The development maintains the natural processes and protective function of
and the protective function of landforms vegetation that previously existed for the site.
and vegetation that can mitigate risks
associated with the natural hazard.
10.0 Recommendations
1. That any new residential building and any other building within 6m of it, shall be constructed in
accordance with AS3959-2009 and the guidelines provided in Section 6.3 of this BMP. With a 12m
(minimum) setback between dwellings and unmanaged fuel Areas 2, 3 and 4, BAL 29 construction is
shown to be viable under Method 2 of AS3959-2009. With a minimum setback of 10m between the
dwelling on Lot 2 and unmanaged fuel Area 1, BAL 29 is viable.
All other structures built within 6m of a dwelling shall be constructed in accordance with this
Standard.
Builders shall warrant that they have a copy of this Standard, and that it shall be used consistently
throughout the design and construction of any residential building or structure built within 6m of the
residence.
2. The Asset Protection Zones on the Subject Lot described in Sections 6.3 and 7.2 of this report shall
be constructed and maintained as IPA.
3. A minimum of 5 000litres of water to be dedicated to fire fighting use at each dwelling. As this
volume is marginal or deficient for structural fire, it is recommended that the Lot owners consider
providing a dedicated supply of 10 000litres of water, within 6m of a hard stand area which is
accessible to fire fighting vehicles. When held in a tank, it should be fitted with a 50mm male
camlock coupling and ballvalve to facilitate access by emergency services. This water reserve should
be supported by a pump that is powered independently of mains electricity supply..
4. Unit buyers shall be made aware of the existence of this Plan and their responsibilities outlined within
it, in particular building construction, asset protection zone maintenance and emergency
management.
Report compiled by Bushfire Risk Reducers for Kenlynn Pty Ltd, August 2016 Page 27