Table 2: Summary of modelling results.
 Case      Figure    Description                      FOS                Comments
                                                            The FOS value of 0.9 above the erosion cut indicates slope
                                                            failure. A vertical erosion cut will likely lead to a series of
                                                            retrogressive upslope translational failures in the loose or
            Figure   Vertical cut into slope                medium dense sand, the exact nature of which will depend
Case 1                                                0.9
              B1     caused by erosion                      on the impact of vegetation and localised variation in ground
                                                            conditions. The slip surface shown is considered a likely
                                                            outcome based on our previous experience in similar
                                                            Situations.

                     Lower slope failure
                                                            Following reprofiling of the slope as a result of the initial
                     following reprofiling of slope
            Figure                                          lower failure, retrogressive failure of the slope is likely (FOS
Case 2               due to failure from Case 1       0.8
              B2                                            values of 1 or less indicate failure).



                   Retrogressive upper slope                Following reprofiling of the slope as a result of the
                                                            downslope translational failure(s), further instability of the
            Figure failure following reprofiling
 Case 3            of slope due to lower              1.0   upper slope is likely (FOS values of 1 or less indicate
              B3
                   translational failure from               failure). Such failure is likely to extend under the proposed
                   Case 2                                   pool if founded on shallow footings.
                     Stability analysis                     If the pool is supported on appropriately designed micro-
                     following reprofiling of               piles, the potential critical slip surface takes the form of a
            Figure
Case 4               slope from Case 1 and            1.6   deep- seated failure. However the FOS is acceptable, even
              B4
                     Case 2, with the pool                  with a reprofiled slope following the erosion cut and
                     supported on micro-piles               subsequent retrogressive failures from Cases 1 and 2



7.0       RECOMMENDATIONS
It is recommended that the proposed pool is supported on micro-piles founded into the underlying natural
dense or very dense sand, as per the recommendations below. The micro-piles will also improve the overall
stability of the dune in this area and will not impact adjacent properties.
Conceptual micro-pile design provided by PCA ground Engineering is attached in Appendix C. Detailed
design will be required by the piling contractor.
The micro-pile system should comprise an ‘A-frame’ structure at the eastern edge of the pool, including one
vertical and one raked pile to resist potential lateral movement in the sands, tied together with a steel-
reinforced concrete capping beam. A row of vertical piles and capping beam is recommended along the
western edge. Grout ‘columns’ should be installed between the micro-piles to prevent flow of sand between
piles. The piles should be at least 10 m deep, with minimum preliminary spacings as shown in Appendix C.
Micro-piles have been successfully used in similar slope stabilisation/remediation projects, including the Park
Road boardwalk and slope stabilisation in Noosa Heads and for a residential development at the northern
end of Seaview Terrace. Micro-piles are able to be installed using small installation equipment to suit the
site’s access constraints.
The following additional recommendations are made for the proposed development:

    ▪ Disturbance to the surrounding slopes should be kept to a minimum (vegetation must
          be maintained below the proposed pool)
    ▪ Revegetation of any bare slopes around the development should be undertaken
    ▪ Additional fill must not be placed on the slope
    ▪ Excavations into the upper slope should be limited, with adequate
          temporary/permanent support provided. Excavations in the middle or lower portions
          of the slope must be avoided



J000867-003-R-Rev0                                          Page 9

                                                            064
                                                                                                                               73

Used in these records

About this file

File size
7.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

24-01-2020 - Appeal No. 245 of 2019 - Final Order of Judge Rackemann.pdf · 7.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.