                                                                                                                                                                                                                                                                                          5m            4       3         2          1




  Timber framed walls to be constructed in accordance with structural
  engineers design and detail. Walls to have Hebel wall panels finished                                                                                                                                                              Timber/steel framed roof to be in accordance with structural
  with acrylic render system with fine sand finish and painted.                                                                                                                                                                      engineers design and detail. Provide COLORBOND® steel
                                                                                                                                                                                                                                     folded standing seam roof with fall to COLORBOND® steel
  COLORBOND® steel Custom Orb oof sheeting to be fixed in                                                                                                                                                                            folded eave gutter in accordance with hydraulic engineers
  accordance with manufacturers specifications.                                                                                                                                                                                      design and detail.
                                                                                                                                                                                                                                     STRATCO 200mm Edge gutters in COLORBOND® steel to be
  Timber/steel framed roof to be in accordance with structural engineers                                                                                                                                                             fixed in accordance with manufacturers specifications. 180 x
  design and detail. Provide COLORBOND® steel folded standing seam                                                                                                                                                                   30mm h3 treated primed timber fascia. Gutters to have 10mm
  roof with fall to COLORBOND® steel folded eave gutter in accordance                                         9,445
                                                                                                                                                                                                                      5.0°           spacers to fascia to provide overflow point.
  with hydraulic engineers design and detail.                                                8,920                                                                                                                           8,920
 8,500
 Ceiling                                                                                                                                                                                                                             Anodised aluminium framed screen with 25 x 25mm
                                                                                                                                                                                                                                     Hinoki Knotwood aluminium battens to each side of
  Fabriacted anodised aluminium 50 x 10mm [email protected] cts. with 70 x 10mm top rail to provide




                                                                                                                                                                                                                                                                                                2,740
  balustrade in accordance with ABCB Housing                                                                                                                                                                                         Timber framed walls to be constructed in accordance




                                                                                                                                     o/a building height above ngl
  Provisions Standard 2022 : 11.3. Balustrade to be a                                                                                                                                                                                with structural engineers design and detail. Walls to
  min. 1000mm high above finished floor level.                                                                                                                                                                                       have Hebel wall panels finished with acrylic render
                                                                                             5,840                           5,840                                                                                           5,840   system with fine sand finish and painted.
 5,760




                                                                                                                                                 7,795
 First floor


                                                                       4,450                                                                                                                                                 4,450




                                                                                                                                                                                                                                                                                                3,060
                                                                                                                                                                                                                                                                                        3,650


 2,700
 Ground floor

                                               1,650                                                                                                                                                                                 Concrete block wall to be in
                                                                                                                                                                                                                                     accordance with structural
  Knotwood Hinoki aluminium battens to form fence/gate. Battens to be
                                                                                                                                                                                                                                     engineers design and detail.
  100 x 25mm sections (125mm max. spacing typical) to have
                                                                                                                                                                                                                                     Provide Crackenback stone facing
  concealed fixings in accordance with manufacturers specifications.
                                                                                                                                                                                                                                     by Eco outdoor.
  Panels to be self-supported with 12mm threaded rods & 20mm
  anodised aluminium spacer set down 300mm from top of battens.                                                                                                                                                                      Abodo Vulcan in Sioo:x (Weathered), bandsawn cladding installed in
                                                                                                                                                                                                                                     accordance with manufacturers specifications.
  Double CHS steel column (hdg) to be in accordance with structural
  engineers design and detail.




                                 Southern Elevation
 S                                                             1:100
                                                                                                                                                                                                                                                                     /Users/benthornton/Documents/Cadfiles/2503 - Palazzesi - 9 George/Archicad/
                                                                                                                                                                                                                                                                                                                              15052025/2503.pln
                           sbt designs pty ltd t/a
                           Skale Building Design                               project   Duplex            lot no.                                                         8   DA02   Development application issue                                                     16/5/2025
                                                                                                                                                                                                                                                                                    project number
                           Mobile: 0412 025 657
                                                                               for       Ross Palazzesi    plan no.                                                  RP72243   DA01   Development application issue                                                     25/3/2025
                                                                                                                                                                                                                                                                                    2503
skale skale.com.au
                                                                                                                                                                               TP02   Planning issue                                                                    16/3/2025
                                                                                         9 George Street   drawn                                                         BT
                                                                                                                                                                               TP01   Planning issue                                                                    12/3/2025
                                                                                                                                                                                                                                                                                    drawing number
                           [email protected]
   building design         A.C.N. 123 976 296 QBCC: 1143 609                   at        Noosaville        scale      (A3)                                             1:100   Rev    Details                                                                               Date    10           DA02                   © Skale Building Design

Used in these records

About this file

File size
10.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

proposal plans.pdf · 10.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.