5m 4 3 2 1
Timber framed walls to be constructed in accordance with structural
engineers design and detail. Walls to have Hebel wall panels finished Timber/steel framed roof to be in accordance with structural
with acrylic render system with fine sand finish and painted. engineers design and detail. Provide COLORBOND® steel
folded standing seam roof with fall to COLORBOND® steel
COLORBOND® steel Custom Orb oof sheeting to be fixed in folded eave gutter in accordance with hydraulic engineers
accordance with manufacturers specifications. design and detail.
STRATCO 200mm Edge gutters in COLORBOND® steel to be
Timber/steel framed roof to be in accordance with structural engineers fixed in accordance with manufacturers specifications. 180 x
design and detail. Provide COLORBOND® steel folded standing seam 30mm h3 treated primed timber fascia. Gutters to have 10mm
roof with fall to COLORBOND® steel folded eave gutter in accordance 9,445
5.0° spacers to fascia to provide overflow point.
with hydraulic engineers design and detail. 8,920 8,920
8,500
Ceiling Anodised aluminium framed screen with 25 x 25mm
Hinoki Knotwood aluminium battens to each side of
Fabriacted anodised aluminium 50 x 10mm [email protected] cts. with 70 x 10mm top rail to provide
2,740
balustrade in accordance with ABCB Housing Timber framed walls to be constructed in accordance
o/a building height above ngl
Provisions Standard 2022 : 11.3. Balustrade to be a with structural engineers design and detail. Walls to
min. 1000mm high above finished floor level. have Hebel wall panels finished with acrylic render
5,840 5,840 5,840 system with fine sand finish and painted.
5,760
7,795
First floor
4,450 4,450
3,060
3,650
2,700
Ground floor
1,650 Concrete block wall to be in
accordance with structural
Knotwood Hinoki aluminium battens to form fence/gate. Battens to be
engineers design and detail.
100 x 25mm sections (125mm max. spacing typical) to have
Provide Crackenback stone facing
concealed fixings in accordance with manufacturers specifications.
by Eco outdoor.
Panels to be self-supported with 12mm threaded rods & 20mm
anodised aluminium spacer set down 300mm from top of battens. Abodo Vulcan in Sioo:x (Weathered), bandsawn cladding installed in
accordance with manufacturers specifications.
Double CHS steel column (hdg) to be in accordance with structural
engineers design and detail.
Southern Elevation
S 1:100
/Users/benthornton/Documents/Cadfiles/2503 - Palazzesi - 9 George/Archicad/
15052025/2503.pln
sbt designs pty ltd t/a
Skale Building Design project Duplex lot no. 8 DA02 Development application issue 16/5/2025
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. RP72243 DA01 Development application issue 25/3/2025
2503
skale skale.com.au
TP02 Planning issue 16/3/2025
9 George Street drawn BT
TP01 Planning issue 12/3/2025
drawing number
[email protected]
building design A.C.N. 123 976 296 QBCC: 1143 609 at Noosaville scale (A3) 1:100 Rev Details Date 10 DA02 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.