5m 4 3 2 1
Abodo Vulcan in Sioo:x (Weathered), bandsawn cladding installed in
accordance with manufacturers specifications. Timber/steel framed roof to be in accordance with structural engineers
design and detail. Provide COLORBOND® steel folded standing seam
roof with fall to COLORBOND® steel folded eave gutter in accordance
COLORBOND® steel Custom Orb oof sheeting to be fixed in
with hydraulic engineers design and detail.
accordance with manufacturers specifications.
2,013 2,013 STRATCO 200mm Edge gutters in COLORBOND® steel to be fixed in
bdy to roof 9,445 bdy to roof accordance with manufacturers specifications. 180 x 30mm h3 treated
top of roof primed timber fascia. Gutters to have 10mm spacers to fascia to
5.0° 5.0° provide overflow point.
8,920
8,500
Ceiling
Anodised aluminium framed screen with 25 x 25mm Anodised aluminium framed screen with 25 x 25mm Hinoki Knotwood
Hinoki Knotwood aluminium battens to each side of aluminium battens to each side of frame.
2,740
frame. 1,513
o/a building height above ngl
1,513
bdy to roof bdy to roof Abodo Vulcan in Sioo:x (Weathered), bandsawn cladding installed in
accordance with manufacturers specifications.
5,840 5,840 5,840
5,760
7,795
First floor
Double CHS steel column (hdg) to be in accordance with structural
engineers design and detail.
3,060
Concrete block wall to be constructed in accordance with structural
engineers design and detail. Wall to be finished with acrylic render
system with fine sand finish and painted.
2,700
Ground floor
Concrete block wall to be constructed in accordance with structural Timber framed roof to be constructed in accordance with structural
engineers design and detail. Wall to be finished with acrylic render engineers design and detail. Roof fascia to have Hebel wall panels
system with fine sand finish and painted. finished with acrylic render system with fine sand finish and painted.
Concrete driveway to be in accordance with structural engineers
design and detail. Provide selected coloured/feature exposed
aggregate blend to manufacturers specifications. Driveway to comply Garage tilt door with Abodo Vulcan in Sioo:x (Weathered), bandsawn
with AS2890.1. Driveway to connect to existing crossover in cladding installed in accordance with manufacturers specifications.
accordance with local authority regulations. Driveway grades to be in
accordance with AS2890.1.
Eastern Elevation
E 1:100
/Users/benthornton/Documents/Cadfiles/2503 - Palazzesi - 9 George/Archicad/
15052025/2503.pln
sbt designs pty ltd t/a
Skale Building Design project Duplex lot no. 8 DA02 Development application issue 16/5/2025
project number
Mobile: 0412 025 657
for Ross Palazzesi plan no. RP72243 DA01 Development application issue 25/3/2025
2503
skale skale.com.au
TP02 Planning issue 16/3/2025
9 George Street drawn BT
TP01 Planning issue 12/3/2025
drawing number
[email protected]
building design A.C.N. 123 976 296 QBCC: 1143 609 at Noosaville scale (A3) 1:100 Rev Details Date 09 DA02 © Skale Building Design
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 10.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.