NOOSA COUNCIL
REFERENCE DOCUMENT
EXE25/0032 25 AUG 2025
JANE PROPERTY
144 Eumundi Noosa Rd, Noosaville QLD 4566
DRAWING REGISTER:
ARCHITECTURAL DRAWINGS
COUNCIL ANNOTATION: DRG NO. DESCRIPTION REV
Exemption Certificate EXE25/0032
AS.75 A000 COVER PAGE, GENERAL NOTES & DRAWING REGISTER C3 C3
only relates to the replacement of the
existing roof and upgrade of ground AS.75 A001 GENERAL NOTES C1
floor toilets from code assessment for
AS.75 A010 SITE PLAN: EXISTING & DEMOLITION C1
building works within the Medium
Impact Industry Zone. AS.75 A011 SITE PLAN: PROPOSED C2 C3
AS.75 A040 FINISHES SCHEDULE C2
AS.75 A100 FLOOR PLAN: EXISTING C1
AS.75 A101 FLOOR PLAN: PROPOSED C1
AS.75 A102 FLOOR PLAN: SETUP PLAN C1
smoke spreading from the enclosure. AS.75 A105 FLOOR PLAN: FLOOR & WALL FINISHES C1
GENERAL NOTES
7. Exit signs and emergency lights to comply with AS2293.1-2018.
1. Design and construction of timber framing in accordance with AS 1684.2, 3 & 4 - 2010. 15. Exit doors which swing against the direction of exit travel to be capable of being held in the open AS.75 A110 REFLECTED CEILING PLAN C1
8. All required exit or path of travel to an exit to have a minimum unobstructed height of 2m except position.
2. All dimensions are measured from the finished wall surface. the unobstructed height of any doorway may be reduced to not less than 1980mm and AS.75 A120 ROOF PLAN C1
minimum width not less than 1.0m or 850mm to allow for disabled access. 16. All penetrations through fire rated members to be sealed using fire collars or fire seal as
3. Glazing to be in accordance with AS1288-2021 and AS2047-2014. appropriate, in accordance with Spec 13.15, NCC2022. AS.75 A200 ELEVATION A: EXISTING AND PROPOSED C1
9. Portable fire extinguishers to comply with AS2444-2001. Provide 2a 20b (E) Dry Chemical
4. All full glazed doors, sidelights, including any glazing capable of being mistaken for a doorway Portable Fire Extinguisher within 2m to 20m of all Electrical Switchboards. 17. A 1 metre clear exit path is needed to be maintained throughout the building. AS.75 A201 ELEVATIONS B & C: EXISTING C1
or opening, shall be clearly marked for their full width a solid non transparent contrasting line.
The contrasting line shall be not less than 75mm wide and shall extend across the full width of 10. Artificial lighting to comply with AS1680.0-2009. 18. Artificial lighting to comply with Part J7, NCC2022(Artificial lighting energy efficiency).
AS.75 A202 ELEVATION D: EXISTING AND PROPOSED C1
the glazing panel. The lower edge of the strip shall be located 900mm from the finished floor
level. Any contrasting line on the glazing shall provide a minimum of 30% luminance contrast 11. Mechanical Ventilation System to comply with AS1668.2-1991, AS1668.2-2012 (as applicable) 19. Coolrooms and freezers will be provided with the following in accordance with Clause G1.2,
and AS/NZS3666.1-2011. NCC2022; AS.75 A300 BUILDING SECTION 01 C1
when viewed against the floor surface or surface within 2m of the glazing on the opposite side.
• door openings not less that 600mm in width and a clear height not less than 1.5m,
5. Wet areas are to be impervious to water i.e. wall surfaces and substrates: of shower enclosures, 12. Minimum 2400mm ceiling height to all new portions of ceiling. • doors which are capable of being opened by hand from inside without a key, AS.75 A400 ACCESSIBLE TOILET DETAILS AND SCHEDULES C1
or if unenclosed, within 1.5m horizontally from the fixture and to a height of 1.8m above the • internal lighting controlled only by a switch located adjacent to the inside of the entrance
floor; and behind any bath, basin, sink etc if within 75mm of a wall to a height of 150mm above 13. Fire indices of materials, linings and surface finishes to comply with Specification Spec 7 doorway, AS.75 A401 ACCESSIBLE TOILET ELEVATIONS C1
the fixture. NCC2022. • indicator lamp positioned outside which is illuminated when the internal lights are
switched on, and AS.75 A600 JOINERY DETAILS: KITCHENETTE C1
6. Floors of bathrooms, WC’s and laundry need to be waterproofed in accordance with 14. Electrical switchboards located in the path of travel to exits to be enclosed in non-combustible • an alarm device located outside but controllable only from within the chamber
AS3740-2021. construction or a fire protective covering with doorways or opening suitably sealed against AS.75 A700 DOOR SCHEDULE C1
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No.
sections of technical specification.
C2 DRAWING REGISTER UPDATED AS CLOUDED 12.02.2025 144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
C3 DRAWING REGISTER UPDATED AS CLOUDED 10.04.2025 description : - A000
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
COVER PAGE & DRAWING REGISTER Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C3
Version: 1, Version Date: 13/08/2025
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of pages 2 to 9 (of 16)
Page 2
GENERAL NOTES:
- BUILDER / SHOPFITTER TO CHECK EXISTING CONDITIONS PRIOR COMMENCEMENT OF WORK. - ALL ITEMS REQUIRED FOR COMPLETION OF WORKS THAT MAY NOT BE MENTIONED OR DESCRIBED IN - DEMOLITION WORKS CARRIED OUT TO BE PREPARED & READY FOR NEW WORKS AS PER APPROVAL PRIOR TO ORDERING
- BUILDER/SHOP FITTER TO CONTACT & COORDINATE DIRECTLY WITH CENTRE MANAGEMENT / DETAIL IN THE CONSTRUCTION ISSUE DRAWINGS, THAT ARE NECESSARY OR INCIDENTAL FOR THE DOCUMENTATION DRAWINGS REQUIREMENTS & ALL SURFACES BE MADE GOOD FOR NEW WORKS. - REFER TO CLIENT/ EQUIPMENT SUPPLIER FOR EXACT TYPE OF EQUIPMENT/ SPECIFICATIONS & SIZE.
LANDLORD SITE ACCESS & HOURS OF WORK & SECURITY ETC. COMPLETION OF WORKS SHALL BE INCORPORATED AND MUST CONFORM TO GOOD BUILDING TRADE - EXISTING LIGHTS, AIR REGISTERS, EMERGENCY LIGHTS AND SPRINKLERS TO REMAIN, EXCEPT WHERE - SHOP FITTER TO CONFIRM LEAD-TIME FOR SPECIFIED PRODUCTS UPON APPOINTMENT TO PROJECT TO
- COUNCIL /BUILDING APPROVAL APPLIES TO THESE WORKS AND IS THE RESPONSIBILITY OF OTHERS. PRACTICES & N.C.C STANDARDS , MANUFACTURES WRITTEN & RECOMMENDATIONS WHERE INDICATED. AVOID DELAYS IN COMPETITION OF WORKS.
(UNLESS OTHERWISE ADVISED) TENANTS / BUILDER TO ARRANGE FOR FINAL INSPECTION FROM LOCAL APPLICABLE - FINAL LOCATIONS OF EMERGENCY LIGHTS, SWITCHBOARD TO BE IN ACCORDANCE WITH AS 2118.1 - USE NON-TOXIC LOW VOC PAINT FOR ALL PAINTED SURFACES.
LAW AUTHORITIES IE- HEALTH/BUILDING INSPECTOR PRIOR TO OCCUPATION OF PREMISES - ALL MANUFACTURED SYSTEMS EG. SUSPENDED CEILING SYSTEMS, SLIDING DOORS INSTALLATIONS AUTOMATIC FIRE SPRINKLER SYSTEMS GENERAL SYSTEMS. CERTIFICATION OF THESE ALTERATIONS - ELECTRICIAN TO INSTALL RELAY NEXT TO ALARM PANEL LOCATION IN ORDER FOR SHOPS MAIN
- EXISTING SERVICES THAT NEED TO BE RELOCATED ,TERMINATED OR REMOVED ARE TO BE CHECKED AND THE LIKE ARE TO BE INSTALLED STRICTLY IN ACCORDANCE WITH THE MANUFACTURERS ARE TO BE PROVIDED TO THE RELEVANT BUILDING SURVEYOR PRIOR TO OCCUPANCY PERMIT ISSUE. LIGHTS TO COME ON WHEN AN ALARM IS ACTIVATED
ON SITE AGAINST AND OR AGAINST ENGINEERS DRAWINGS PRIOR TO THE COMMENCEMENT OF ANY SPECIFICATIONS FOR THAT SYSTEM. - ALL EXISTING ELECTRICAL SERVICES THAT ARE NOT INDICATED ON PLAN ARE TO BE RELOCATED AND - ELECTRICIAN TO INSTALL PHONE LINE CONNECTION & POWER FOR ALARM PANEL NEXT TO THE PANEL
WORKS - WHERE CHANGE IN CEILINGS/CEILING HEIGHTS IN EXISTING/PROPOSED APPLICATIONS - EXTEND ALL OR REMOVED AND AREA TO BE MADE GOOD FOR NEW WORKS. LOCATION.
- DOCUMENTATION DRAWINGS ARE TO BE READ IN CONJUNCTION WITH ANY STRUCTURAL, MECHANICAL DUCTWORK, SPRINKLERS, HYDRAULIC SERVICES ECT. TO SUIT PROPOSED WORKS - SHOP FITTERS COMMUNICATION CONTRACTORS TO RUN ALL CABLING FOR PHONE LINES AND TO - ALARM CONTRACTOR TO SUPPLY AND INSTALL SECURITY CAMERAS. SHOP FITTER TO LIAISE WITH
MECHANICAL AND ELECTRICAL ENGINEER'S DRAWINGS. - DEMOLITION WORKS-PRIOR TO BEING BE CARRIED OUT IN ACCORDANCE WITH DEMOLITION CODE OF COORDINATE WITH TELSTRA / SIMILAR APPROVED COMMUNICARIO SUPPLIERS -TO DO FINAL CLIENT & SECURITY CONTRACTOR FOR COORDINATION OF THESE WORKS. ALARM EQUIPMENT AND
- EXISTING LIGHTS, AIR REGISTERS, EMERGENCY LIGHTS AND SPRINKLERS TO REMAIN, EXCEPT WHERE PRACTICE - SAFE WORK AUSTRALIA.WHS ACT . BUILDER/CONTRACTOR TO READ ANY ENGINEER'S CONNECTION ONLY AT IDP. CABLING WITHIN TENANCY TO BE SUPPLIED AND INSTALLED BY SECURITY CONTRACTOR.
INDICATED. STRUCTURAL DRAWINGS WHERE DEMOLITION REQUIRED OR ANY RESTRICTIONS TO DEMOLITION - CLIENT TO COORDINATE THE PHONE / INTERNET LINES WITH COMMUNICATION PROVIDER.
- BUILDER/SHOP FITTER TO PROVIDE STRUCTURAL ENGINEERS DRAWINGS , COMPUTATIONS & WORKS REQUIRED. - UPON KNOWLEDGE OF NON STOCKED ITEMS ANY ALTERNATIVE PRODUCTS ARE TO BE SELECTED BY COUNCIL ANNOTATION:
CERTIFICATE FOR ALL CEILING & SHOP FRONT / GLAZING WORKS AS REQUIRED. - REMOVE ALL EXISTING SHOP FIXTURES TO EXISTING STORE AS REQUIRED / WHERE APPLICABLE. THE SHOP FITTER AS SOON AS POSSIBLE AND SUBMITTED TO THE DESIGNER AND CENTRE FOR
Exemption Certificate EXE25/0032
STRUCTURAL NOTES:
- ALL SUSPENDED CEILING DESIGNS TO CONFORM WITH AS 2785- SUSPENDED CEILINGS - DESIGN AND - SHOP FITTER TO PROVIDE STRUCTURAL ENGINEERS DRAWINGS, COMPUTATIONS & CERTIFICATE FOR - ANY STEEL STRUCTURAL WORKS TO BE IN ACCORDANCE WITH DESIGN STANDARDS AS 4100 STEEL only relates to the replacement of the
INSTALLATION. ALL SUSPENDED CEILINGS/BULKEADS/ SHOP FRONT /GLAZING WORKS AS REQUIRED. STRUCTURES. existing roof and upgrade of ground
FIRE NOTES: floor toilets from code assessment for
- ALL COMMERCIAL BUILDINGS IN AUSTRALIA ARE REQUIRED TO MEET - BUILDER/ CONTRACTOR TO SUPPLY & INSTALL BUT NOT LIMITED TO - 2A4F (9L) WET CHEMICAL FIRE - ALTERATIONS TO FIRE ALARM ARE TO BE CARRIED OUT IN ACCORDANCE WITH AS 1670. LOCATION OF - THE NATIONAL CONSTRUCTION
building CODEworks
- FIRE SAFETY ELEMENT
within theMUST BE TESTED TO CERTAIN
Medium
THE STANDARDS LAID OUT IN THE BUILDING CODE OF AUSTRALIA. THIS INCLUDES STRICT EXTINGUISHER OR 40B(E) (4.5 KG.) DRY CHEMICAL POWDER EXTINGUISHER ADJACENT TO COOKING SMOKE DETECTOR & GENERAL SPRINKLER HEADS TO BE DETERMINED BY NOMINATED CONSULTANT SPECIFICATIONS (I.E. AS1530.4) ALL PROPOSED MATERIALS ARE TO MEET RESISTANCE APPROVALS
REGULATIONS REGARDING THE FIRE SAFETY SYSTEMS AND ELEMENTS OF COMMERCIAL BUILDINGS. EQUIPMENT AND 2A20B(E) (2KG) OR 2A 40B(E) (4.5K) DRY CHEMICAL EXTINGUISHER ADJACENT TO ALL NEW AND ALTERATION WORK TO BE CARRIED OUT BY A REGISTERED FIRE SERVICES CONTRACTOR Impact
AND CERTIFICATION. "FIRE RATING" Industry
OR "FIRE RESISTANCE Zone.
LEVEL" (FRL). ALL PERMANENT FINISHES EG.
ALL FIRE-RATED MATERIALS USED IN COMMERCIAL BUILDINGS MUST COMPLY WITH AS4072.1 AND ELECTRICAL SWITCHBOARD IN ACCORDANCE TO AS. 2444 & BCA E1.6. TENANT CONTRACTOR TO AND ARE TO COMPLY STRICTLY WITH AS 1668.2 7 AS3666.1 VINYL, FABRICS/LAMINATES/ACOUSTIC CEILING TILES/ FLOORING MATERIALS - WALL MATERIALS
AS1530.4. INSTALL APPROPRIATE SIGNAGE AS REQUIRED - ENSURE SPRINKLER HEADS NOT TO BE PAINTED. -CLADDING ETC ARE REQUIRED TO COMPLY WITH SPECIFICATION C1.10 OF THE BCA / NCC
MECHANICAL NOTES:
- ANY ALTERATIONS TO THE MECHANICAL VENTILATION AND EXHAUST SYSTEM TO BE CARRIED OUT IN Mechanical ventilation for acceptable indoor-air quality AS 3666.1 & AS 1668.2. CONTRACTORS/CONSULTANTS BASED ON THERE ADVISE AND OR DRAWINGS/REPORTS/SPECIFICATIONS PROVIDED TO THE RELEVANT BUILDING SURVEYOR PRIOR TO OCCUPANCY PERMIT ISSUE.
ACCORDANCE WITH AS 1668 & AS 3666. & NCC PART 3.8.5 HEALTH & AMMENITITY - VENTILATION. - CERTIFICATION OF THESE ALTERATIONS ARE TO BE PROVIDED TO THE RELEVANT BUILDING SURVEYOR PROVIDED -WHERE APPLICABLE .
- ALTERATIONS TO THE MECHANICAL VENTILATION SYSTEM ARE TO BE CARRIED OUT IN ACCORDANCE PRIOR TO OCCUPANCY PERMIT ISSUE. - ALTERATIONS TO THE SPRINKLER SYSTEM ARE TO BE CARRIED OUT IN ACCORDANCE WITH AS 2118.1
WITH THE USE OF MECHANICAL VENTILATION AND AIR - CONDITIONING IN BUILDINGS PART 2: - MODIFICATIONS TO MECHANICAL/ SPRINKLER SERVICES TO BE ADVISED BY THE RELEVANT BY A REGISTERED FIRE SERVICE CONTRACTOR. CERTIFICATION OF THESE ALTERATIONS ARE TO BE
HYDRAULIC / WATERPROOFING NOTES:
- ENSURE THAT ALL HYDRAULIC WORKS COMPLY WITH RELEVANT AUSTRALIAN STANDARDS AND BCA - WET AREAS TO BE IMPERVIOUS TO WATER IF WITHIN 75MM OF A WALL TO A HEIGHT OF 150MM - BATHROOM, SHOWER, SINK , LAUNDRY OR SANITARY COMPARTMENT TO BE WATER RESISTANT OR - INTERNAL HOT WATER SYSTEMS ARE TO BE MOUNTED ON METAL LEGS 200MM ABOVE FFL. OR AS
/N.C.C WATERPROOFINGS MEMBRANES Part 1 Materials (AS 4654.1-2012) IS TO ENSURE THAT THE ABOVE FIXTURES.WATERPROOF MEMBRANE TO BE INSTALLED AS REQUIRED WATER PROOF IN ACCORDANCE WITH AS 3740 REQUIRED BY MANUFACTURER.
MATERIAL PROPERTY OF THE MEBRANE IS WATERPROOF - IMPERVIOUS TO MOISTURE , AND REMAINS - PROVIDE WATER PROOF MEMBRANE & OR WATERPROOF SEALER TO FULL EXTENT OF WET AREAS / - HAND WASH BASIN TO HAVE FLOW CONTROL OF 2L/MIN WITH TIME CONTROL OF 7.5 SECONDS. EACH - TOILETS TO BE DUAL FLUSH WITH MAXIMUM OF 3.5 L FLUSH.
WATERPROOF UNDER A VARIETY OF SITUATIONS EXPOSURES AND CONDITIONS. WALLS & FLOOR SURFACE- WRAP MEMBRANE UP WALLS 1 METER MIN FROM FFL. HAND WASH BASIN MUST BE PROVIDED WITH A LIQUID SOAP DISPENSER TOGETHER WITH A HAND - ALL MR MDF MATERIALS TO BE USED IN WET ARES /WATER RESISTANT TO WET AREAS.
- BATHROOM, SHOWER, SLOP HOPPER, SINK COMPARTMENT, LAUNDRY OR SANITARY COMPARTMENT - ALL WALL AREAS IN WET AREAS , ARE TO BE FINISHED WITH SUITABLE IMPERVIOUS MATERIAL TO A TOWEL DISPENSER
TO BE WATER RESISTANT OR WATER PROOF IN ACCORDANCE WITH AS 3740. & NCC PART 3.8.1 HEALTH MINIMUM HEIGHT OF 1.8M ABOVE FFL. WALL AREAS ABOVE 1.8M ARE REQUIRED TO BE PAINTED WITH - MEDIUM USE KITCHEN SINK TAP TO HAVE FLOW CONTROL OF MAXIMUM 8L/MIN WITH ACTUATED
& AMENITY -WET AREAS AND EXTERNAL WATERPROOFING WASHABLE PAINT CONTROL.
ELECTRICAL / LIGHTING COMPLIANCE:
- ALL ARTIFICIAL LIGHTING TO COMPLY WITH AS 1680 INTERIOR ADN WORKPLACE LIGHTING & NCC AS 3000.ELECTRICAL INSTALLATIONS (KNOWN AS THE AUSTRALIAN / NEW ZEALAND WIRING RULES). - EXIT & EMERGENCY LIGHT TO BE ON SEPARATE CIRCUIT & HAVE SEPARATE TIMER FOR TESTING. - SWITCHING OF LIGHTS TO BE ZONED AS INDICATED ON DRAWINGS OR TO BE CONFIRMED WITH
PART J6.2 ARITIFICIAL LIGHTING REQUIREMENTS AND POWER & PART 3.8.4 HEALTH & AMMENITY - - ANY ELECTRICAL OUTLET REQUIRED FOR CLIENT SUPPLIED EQUIPMENT - REFER TO THE - BUILDER TO SUPPLY & INSTALL EMERGENCY LIGHTS & EXIT LIGHTS.WHERE APPLICABLE. DESIGNER
LIGHT. LIGHTING AT ENTRANCES THAT HAS A HIGHER LUX LEVEL THAN THE SURROUNDING LIGHTING MANUFACTURES /SUPPLIERS REQUIRMENTS SPECIFIC LOCATIONS OF THE GPO/DATA OUTLETS. ALLOW - ALL ELECTRICAL INSTALLATIONS MUST BE INSTALLED ACCORDING TO AUSTRALIAN STANDARDS AS - PROVIDE AFTER HOURS DISPLAY LIGHTING TO SHOP FRONT AND INTERNAL DISPLAY COLUMNS.
TO ASSIST WITH IDENTIFICATION AND SAFETY. FOR SUPPLY AND INSTALLATION OF ALL GPOS/DATA TO ALL EQUIPMENT/MACHINERY REQUIRING 3000. WHERE APPLICABLE/TIMER TO BE FITTED TO AFTER HOURS LIGHTING WHERE/IF REQUIRED.
- LIGHTING LAYOUT TO BE APPROVED BY TENANT (CLIENT) & TENANT TO ENGAGE A LIGHTING ENGINEER POWER/DATA . CONFIRM ALL GPO/DATA LOCATIONS WITHIN JOINERY UNITS WITH THE CLIENT - ALL EXISTING ELECTRICAL SERVICES THAT ARE NOT INDICATED ON PLAN ARE TO BE RELOCATED AND - EMERGENCY LIGHTS & EXIT SIGNS TO BE IN ACCORDANCE WITH BCA E4.2,E4.4, E4.5, E4.6, AND AS
TO PREPARE APPROPRIATELY DESIGNED LIGHTING LAYOUT . PRIOR TO INSTALLATION/CONSTRUCTION. ALL ELECTRICAL / DATA WIRING/OTHER CABLING TO BE OR REMOVED AND AREA TO BE MADE GOOD FOR NEW WORKS. 2293.1
- INSTALLATION OF EMERGENCY LIGHTING & ILLUMINATED EXIT SIGNS TO BE IN ACCORDANCE WITH AS CONCEALED WITHIN WALLS/FLOORS / JOINERY WHERE REQUIRED.IF CHASING REQUIRED TO FLOOR - NEW SWITCHBOARDS LOCATED WITHIN A PATH OF TRAVEL TO AN EXIT ARE TO ENCLOSED IN NON
2293. ALL ELECTRICAL INSTALLATIONS MUST BE INSTALLED ACCORDING TO AUSTRALIAN STANDARDS -STRUCTURAL ENGINEERS TO CHECK IF CAN BE ACHIEVED WITHIN STRUCTURE. COMBUSTIBLE CONSTRUCTION WITH SMOKE PROOF DOORS. (WHERE APPLICABLE).
DDA / ACCESSIBILITY / EGRESS / DOORS / RAMPS & STAIRS:
- NEW BUILDINGS, AND EXISTING BUILDINGS UNDERGOING BUILDING WORK, MUST TO BE CAPABLE OF BEING OPENED AT ALL TIMES FROM THE SIDE FACING THE PERSON SEEKING EGRESS ANY FULLY GLAZED DOOR OR GLASS WALL THAT COULD BE MISTAKEN FOR AN ENTRANCE. A MINIMUM CLOSING.
COMPLY WITH THE COMMONWEALTH DISABILITY (ACCESS TO PREMISES - BUILDINGS) FROM THE BUILDING WITH A SINGLE HANDED DOWNWARD ACTION ON A SINGLE DEVICE WITHOUT THE 30% LUMINANCE CONTRAST TO THE BACKGROUND IS ALSO REQUIRED. A MAXIMUM FORCE OF 20N AT - A 1M CLEAR PATH IS REQUIRED TO BE MAINTAINED THROUGHOUT TENANCY AS A MINIMUM UNLESS
STANDARDS 2010 (PREMISES STANDARDS) THE USE OF A KEY AND LOCATED BETWEEN 900MM AND 1200MM ABOVE FFL IN ACCORDANCE WITH CLAUSE THE ENTRANCE DOOR HANDLE TO OPEN DOORS, AND DOOR CLOSERS THAT ARE ADJUSTABLE. OTHERWISE REQUIRED TO COMPLY WITH CIRCULATION. A CONTINUOUS ACCESSIBLE PATH OF TRAVEL
PREMISES STANDARDS HAVE BEEN MADE UNDER THE COMMONWEALTH DISABILITY D2.21, BCA 2016 Volume 1 Amendment 1. ANY ENTRANCE BUZZER OR INTERCOM 900 - 1100mm HIGH. FROM THE PROPERTY ENTRANCE AND ANY ONSITE CAR PARK TO PRINCIPAL ENTRANCES.
DISCRIMINATION ACT 1992 (DDA) - DOOR HANDLES WITH 35MM AND NOT MORE THAN 45MM CLEARANCE BETWEEN THE HANDLE (IN THE - INSTALL WEATHER STRIPS TO THE BOTTOM OF ALL EXTERNAL DOORS (IF APPLICABLE) (FOR - ENTRANCE DOORS THAT CAN BE OPENED FROM THE OUTSIDE OF A ROOM IN AN EMERGENCY.
- ACCESS PROVISION PERFORMANCE REQUIREMENT TO BE THAT CONTAINED IN SECTION D, PART E3 CENTRE) AND THE BACK PLATE OR DOOR FACE EXTERNALLY FACING TENANCIES) & TO NEW DOORS ONLY - DOOR CONTROLS THAT CAN BE REACHED BY A PERSON WHEN STANDING OR
AND PART F2 OF THE BCA FOR WHICH THERE IS AN EQUIVALENT PERFORMANCE REQUIREMENT IN THE D OD D STYLE DOOR HANDLE WITH RETURN, INSTALLED AT HEIGHT OF 900 - 1100mm ABOVE FLOOR - RAMPS TO BE CONSTRUCTED ACCORDING TO AS 1428.1- 2009 & N.C.C Part 3.9.1 Stairway and ramp SEATED AND USED WITH A CLOSED FIST OR OPEN PALM AND INCORPORATING RAISED TACTILE AND
ACCESS CODE WITHIN THE MEANING OF THE PREMISES STANDARDS. THE ACCESS CODE REFERENCES LEVEL construction - SAFE MOVEMENT AND ACCESS / STAIRWAY & RAMP CONSTRUCTION BRAILLE ELEMENTS, FOR EXAMPLE, ENTRY BUZZER AND AFTER HOURS ACCESS.
DP1, DP4, DP6, DP8 AND DP9 A MINIMUM 850MM CLEAR OPENING WIDTH AT ENTRANCES WITH CIRCULATION SPACE ON BOTH SIDES - ALL DO0RS AND WINDOWS RO BE INSTALLED IN ACCORDANCE WITH AS2047.1-1996 - DOORS AND - EXIT DOORS WHICH SWING AGAINST THE DIRECTION OF EXIT TRAVEL ARE TO BE CAPABLE OF BEING
RAMPS TO MEET CIRCULATION SPACES AND ANGLES OF APPROACH AT DOORWAYS IN ACCORDANCE THAT CONSIDERS ANGLES OF APPROACH AND INCORPORATES LEVEL LANDINGS (INCLUDING THE WINDOWS / WINDOWS IN BUILDINGS - SELECTION AND INSTALLATION. HELD IN AN OPEN POSITION.
WITH THE RANGE IN AUSTRALIAN STANDARDS. OPERATIVE LEAF OF A MULTIPLE LEAF DOOR). SOLID STRIP A MINIMUM OF 75MM WIDE INSTALLED - DOOR CONTROLS THAT ARE LOCATED ON THE PATH OF TRAVEL TO THE DOOR, TO ALLOW ADEQUATE
- ALL EXIT DOORS AND DOOR IN THE PATH OF TRAVEL TO EXITS (INCLUDING ROLLER SHUTTERS) ARE WITH THE LOWER EDGE AT A HEIGHT OF 900 - 1000mm ABOVE FLOOR LEVEL ACROSS THE WIDTH OF TIME WHEN IN OPERATION FOR A PERSON TO MOVE FULLY THROUGH THE DOOR PRIOR TO THE DOOR
WALLS:
- ALL EXISTING PLASTERBOARD STUD WALLS TO BE RE SANDED & PREPARED AVOID DIFFERENTIAL SHRINKAGE BETWEEN DISSIMILAR MATERIALS, E.G. STEEL TO TIMBER; TIMBER TO - Part C1: Fire resistance and stability AS1170.2 STRUCTURAL DESIGN ACTIONS - WIND ACTIONS
TO BE REPAINTED. MASONRY; AND - ALLOWING FOR SHRINKAGE WITH RESPECT TO PLUMBING. IT IS RECOMMENDED THAT - Part C2 - Compartmentalisation & separation AS1170.4 STRUCTURAL DESIGN ACTIONS - EARTHQUAKE ACTIONS
- TIMBER FRAMING SHALL COMPLY WITH AS 1684 AS APPLICABLE. MUST BE CONSTRUCTED USING A PROFESSIONAL STRUCTURAL ENGINEER BE EMPLOYED TO ADDRESS THE ABOVE ISSUES AND - Part C3 - Protection of openings AS1720.1 TIMBER STRUCTURES - DESIGN METHODS
SPECIFIC METHODS FOR ATTACHMENT OF LININGS TO ACHIEVE FIRE RATINGS GREATER POTENTIAL FOR STRUCTURAL PERFORMANCE IN GENERAL. - THE FOLLOWING STANDARDS AND GUIDELINES SHOULD BE CALLED UPON TO ASSIST:
SHRINKAGE IN TALLER TIMBER BUILDINGS. SHRINKAGE CAN BE MINIMISED BY: - UNSEASONED TIMBER - FIRE - DESIGN REQUIREMENTS Deemed to Satisfy Provisions that meet the above Performance AS1170.0 STRUCTURAL DESIGN ACTIONS - GENERAL PRINCIPLES
OR ENGINEERED TIMBER; CONSTRUCTION BEARERS & JOISTS AT THE SAME PLANE- DETAILING TO Requirements are detailed in the BCA under: AS1170.1 STRUCTURAL DESIGN ACTIONS - PERMANENT, IMPOSED AND OTHER ACTIONS (2002)
GLAZING:
- ALL GLAZING TO COMPLY WITH AS 1288,& AS 2047 & SECTION 'J' - GLASS IN BUILDINGS - SELECTION - VISUAL INDICATORS ON GLAZING AS PER AS1428.1:2009 WHERE THERE IS NO CHAIR RAIL, HANDRAIL SHALL BE NOT LESS THAN 75 MM WIDE AND SHALL EXTEND ACROSS THE FULL WIDTH OF THE GLAZING WHEN VIEWED AGAINST THE FLOOR SURFACE OR SURFACES WITHIN 2 M OF THE GLAZING ON THE
AND INSTALLATION. OR TRANSOM, ALL FRAMELESS OR FULLY GLAZED DOORS, SIDELIGHTS, INCLUDING ANY GLAZING PANEL. THE LOWER EDGE OF THE CONTRASTING LINE SHALL BE LOCATED OPPOSITE SIDE. FROSTED OR TRANSPARENT FILMS MUST NOT BE USED.
- SHOP FITTER TO PROVIDE STRUCTURAL ENGINEERS DRAWINGS , COMPUTATIONS & CERTIFICATE FOR CAPABLE OF BEING MISTAKEN FOR A DOORWAY OR OPENING, SHALL BE CLEARLY MARKED FOR THEIR BETWEEN 900 MM AND 1000 MM ABOVE THE PLANE OF THE FINISHED FLOOR LEVEL. - ENSURE ALL EDGES ARE BEVELED AND POLISHED SMOOTH. (WHERE APPLICABLE).
GLAZING WORKS FULL WIDTH WITH A SOLID AND NON-TRANSPARENT CONTRASTING LINE. THE CONTRASTING LINE - ANY CONTRASTING LINE ON THE GLAZING SHALL PROVIDE A MINIMUM OF 30% LUMINANCE CONTRAST
NOOSA COUNCIL
REFERENCE DOCUMENT
EXE25/0032 25 AUG 2025
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No.
sections of technical specification.
144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A001
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
GENERAL NOTES Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C1
Version: 1, Version Date: 13/08/2025
Page 3
60350
54500 5850
Site Boundary 60.350 115°57'
Site Boundary
Site Boundary
Site Boundary
ME
Z
LEV ZANIN
EL
OVE E
TIMBER SLIPPERS RETAINING WALL
R
EXISTING BUILDING:
ME
REFER TO DRAWINGS FOR
ZZA
205°57'
NIN
FURTHER SCOPE OF WORKS
9950
E
LEV
EL
O
VE
LANDSCAPE
15.088
R
EXISTING
15090
BUILDING
BOXES
MAIL
DP EXISTING MAIL BOXES:
DP CONFIRM LOCATION ON SITE
FHR
23200
CROSSOVER
EXISTING
Roller Door Roller Door Roller Door
REMOVE & REPLACE
5140
EUMUNDI ROAD
25°57'
DP DP DP DP DP DP
EXISTING FIRE HOSE REELS
SB
44.458
Existing Palm Tree
SB Roller Door LOT 1 ON RP 173876
SB
DP PARISH OF TEWANTIN
Awning Over COUNTY OF MARCH
Roof Over
Bol Bol
EXISTING DRIVEWAY
SB
Bol
Roller Door
01
DP Awning Over 03
FHR ALL
W
Roof Over ING
AIN
Bol Bol RET
Bol Bol 04
Roller Door Roller Door
02
DP DP
Awning Over REMOVE & REPLACE 05
Roof Over
44460
Bol
EXISTING FIRE HOSE REELS ALL
06 INGW
AIN
DP 07 K RET
OC
Awning Over 08
C . BL COUNCIL ANNOTATION:
Roof
CON
Over
09
Exemption Certificate EXE25/0032
only relates to the replacement of the
10
°
existing roof and upgrade of ground
270
BIN 18
11
89.
559 floor toilets from code assessment for
AREA 13 12 building works within the Medium
Impact Industry Zone.
CO
FLOOD
LIGHT
NC
17
.B
EXISTING CARPARK:
LOC
REPAIR / MAKE THE EXISTING CONCRETE PAVEMENT
KR
20
671 GOOD TO RECEIVE NEW ASPHALT TOPPING
ETA
ININ
GW
EXISTING LANDSCAPE:
21260
16
ALL
CLEAR TREES AND VEGETATION THAT ARE NOT
LANDSCAPE NATIVE SPECIES INSTALL NEW WATERING SYSTEM TO
BIN
15 COVER ALL AREAS OF LANDSCAPING.
AREA
14
DEMOLITION NOTES: 4. Remove existing RSD’s and shopfronts.
n dary 1. All demolition work, including asbestos removal, 5. Remove existing internal office walls.
Bou shall be carried out by a suitably licensed and 6. Remove existing signage.
Site NOOSA COUNCIL
competent sub-contractor. The works included are 7. Remove existing damaged DP’s, gutters and facias.
REFERENCE DOCUMENT limited to the following items. 8. Remove existing external awnings.
A SITE PLAN: EXISTING EXE25/0032 25 AUG 2025 2. Remove all asbestos as identified in QBM Asbestos 9. Remove existing brick paving to unit entries.
Scale 1:200 @ A3 Materials Report and Register dated 12/07/2022. 10. Remove & replace existing fire hose reels
-
3. Remove existing landscaping and tress.
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No. north
sections of technical specification.
144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
N
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A010
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
SITE PLAN: EXISTING Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C1
Version: 1, Version Date: 13/08/2025
Page 4
60350
54500 5850
Site Boundary 60.350 115°57'
Site Boundary
Site Boundary
Site Boundary
LANDSCAPE
TIMBER SLIPPERS RETAINING WALL
C2
NEW PYLON SIGN:
PA NEW 2 X 2m² NON ILLUMINATED PYLON SIGN.
205°57'
9950
- PROVIDE FOOTINGS TO STRUCTURAL
COUNCIL ANNOTATION: ENGINEER DETAILS
1000 500
Exemption Certificate EXE25/0032 PB NOTE: SUBJECT TO COUNCIL APPROVAL
200
15.088
only relates to the replacement of the EXISTING -
NOTE: FINAL LOCATION TO BE CONFIRMED
15090
existing roof and upgrade of ground BUILDING
BOXES
MAIL
SB
floor toilets from code assessment for EXISTING BUILDING: DP REPLACE EXISTING MAIL BOXES WITH NEW TO
building works within the Medium REFER TO DRAWINGS FOR DP SAME LOCATION (CONFIRM WITH CLIENT IF
Impact Industry Zone.
8540
FURTHER SCOPE OF WORKS FHR
APPLICABLE).
23200
CROSSOVER
EXISTING
5140
EUMUNDI ROAD
25°57'
C.O.S.
5425
DP DP DP DP DP DP
SB
44.458
Existing Palm Tree
SB LOT 1 ON RP 173876
SB
DP PARISH OF TEWANTIN
COUNTY OF MARCH
Roof Over
Bol EXISTING DRIVEWAY SUPPLY & INSTALL STEEL SLIDING
Bol Bol
SB AUTOMATIC SECURITY GATE
01
DP 03
FHR ALL
W
Roof Over ING
AIN
Bol Bol RET
Bol Bol 04
02
DP DP
05 EXISTING CARPARK:
Roof Over
44460
Bol NEW 25mm ASPHALT TOPPING TO EXISTING CONCRETE PAVEMENT TO CIVIL ENGINEER DETAILS.
ALL
GW
06
AININ REPLACE ALL EXISTING BOLLARDS WITH NEW TO SAME LOCATION (CONFIRM WITH CLIENT IF APPLICABLE).
DP 07 K RET PROVIDE NEW LINE MARKING AS PER EXISTING LAYOUT
OC
08
C . BL
Roof
CON LANDSCAPE:
Over
09 PROVIDE NEW LANDSCAPE AND TREES TO LANDSCAPE ARCHITECT DETAILS. INSTALL NEW WATERING SYSTEM
10 TO COVER ALL AREAS OF LANDSCAPING.
°
270
11 559
NEW FENCING:
BIN 18 89.
AREA 13 12 NEW FENCING TO BOUNDARY: 2.1m HIGH ALUMINUM 50X 50 POSTS AND TOP AND BOTTOM RAILS WITH 30 X
NOOSA COUNCIL 30 VERTICALS SPACED NO MORE THAN 100mm CENTRES.
CO
FLOOD
LIGHT NOTE: CONFIRM REQUIRED EXTENT OF FENCING ON SITE
NC
17 REFERENCE DOCUMENT
.B
20
EXE25/0032 25 AUG 2025
LOC
671 CAR PARK LIGHTS:
KR
PROVIDE SOLAR LED CAR PARK LIGHTS. NUMBERS AND LOCATION TO ELECTRICAL / LIGHTING ENGINEER
ETA
ININ
CCTV:
GW
21260
16
200 1000 ALLOW FOR 3 CCTV CAMERAS TO EXTERNAL CAR PARK AREA. LOCATION TO SECURITY CONTRACTOR ADVICE
ALL
LANDSCAPE SIGNAGE:
15
BIN
AREA
1000 W. X 2000 H. NON 144 ALL EXTERNAL AND INTERNAL SIGNAGE TO BE PROVIDED AS PER DESIGN DRAWINGS AND SIGNAGE
ILLUMINATED PYLON SIGN TO MANUFACTURERS SPECIFICATIONS. AND LIMITED TO THE FOLLOWING ITEMS:
MANUFACTURERS DETAILS 1 ABC P/C
8m² ILLUMINATED PYLON SIGN SUBJECT TO COUNCIL SIGNAGE APPROVAL.
2 JANE SMITH
14
TENANCY NUMBERS 1 TO 8 - 600mm IN HEIGHT LASER CUT POWDER COATED ALUMINUM.
3 FRED
2000
2000
ELECTRICAL:
2300
2300
1000 W. X 200 H. NON 4 BOB
INDIVIDUAL SIGN PANELS 5 MICK P/C ALL ELECTRICAL WORKS TO BE CARRIED OUT IN ACCORDANCE WITH AUSTRALIAN STANDARDS AND
6 JACK ELECTRICAL ENGINEERS REQUIREMENTS. THE WORKS INCLUDE AND ARE LIMITED TO THE FOLLOWING ITEMS:
7 MARY NEW SITE MAIN SWITCHBOARD.
8 SMILE Co.
- 3 PHASE 63amp SUPPLY AND SWITCHBOARD TO TENANCIES 1 TO 4
- 3 PHASE 80amp SUPPLY AND SWITCHBOARD TO TENANCIES 5 TO 8
300
300
n dary - 3 X LED HIGH BAY LIGHT FITTINGS TO TENANCIES 1 TO 4.
Bou Council Annotation:
Site - 4 X LED HIGH BAY LIGHT FITTINGS TO TENANCIES 5 TO 8.
Pylon Sign is not subject to - LIGHTING AND GPO’S TO NEW WC’S.
- 1 X 10amp DOUBLE GPO ADJACENT TO EACH TENANCY SWITCHBOARD.
A SITE PLAN: PROPOSED exemption and requires separate PB PYLON SIGN ELEVATION PA PYLON SIGN ELEVATION - POWER SUPPLY TO PYLON SIGN AND TO EACH TENANCY SIGN.
- Scale 1:200 @ A3 approval. - Scale 1:50 @ A3 - Scale 1:50 @ A3 - SOLAR LED CARPARK LIGHTS.
C2 - CCTV TO EXTERNAL CAR PARK AREA,
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No. north
sections of technical specification.
C2 REVISIONS AS CLOUDED 10.04.2025 144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
N
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A011
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
SITE PLAN: PROPOSED Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C2
Version: 1, Version Date: 13/08/2025
Page 5
FINISHES SCHEDULE
NOTE: FINISHES LEGEND & SCHEDULES ARE TO BE READ IN CONJUNCTION WITH SPECIFICATION AND CONSTRUCTION DRAWINGS - REFER TO PLANS, ELEVATION & SECTION DRAWINGS
AS DETAILED AND INTERIOR DESIGNER DRAWINGS. CONTRACTORS ARE TO ENSURE ALL MATERIALS ARE TO BE ORDERED IN TIME TO MEET DEADLINE AS SCHEDULED OR CONTRACTOR
SHALL BEAR THE COST OF AIR FREIGHTING MATERIALS IN TO MEET DEADLINE. ANY FINISHES RE-SELECTING WILL BE CHARGED TO BUILDER AT PER HOUR RATE ON ITEMS
CODE DESCRIPTION FINISH SPECIFICATION LOCATION SUPPLIER SAMPLE IMAGE
NAME: Stramit® Premier 300
Architectural Cladding
COATED PAINT FINISHES
MF METAL WALL CLADDING NEW FASCIA & SOFIT STRAMIT
COLOUR: Standard Steel
METAL
Colorbond® Night Sky®
NAME: BLACK (C/B NIGHT SKY®)
RANGE: Duralloy® DULUX
POWDER
PCB POWDER COATED PAINT WINDOWS & DOORS
CODE: 27219319 https://www.dulux.au/
FINISH: MATT
NAME: VIVID WHITE
WALLS
CODE: SW1G1 DULUX
P1 WALL / CEILING PAINT CEILINGS
FINISH: SEMI GLOSS https://www.dulux.au/
DOORS
LOW SHEEN
NAME: TEAHOUSE
DULUX
P2 DOOR FRAMES PAINT FINISJ: SN4G6 DOOR FRAMES
https://www.dulux.au/
FINISH: GLOSS
ROCKOTE
CF CONCRETE LOOK FINISH NAME: CONCRETE FINISH EXTERNAL WALLS
EPOXY FLOOR PAINTS
https://rockcote.com.au/
INDUSTRIAL STRENGTH EPOXY
RESIN: CONCRETE COLOUR SYSTEMS
FE CCS Defend XT Industrial Epoxy FLOORS
TWO PART, CIVIL GRADE, HIGH www.concretecoloursystems.com.au
SOLIDS EPOXY RESIN COATING
COMMERCIAL GRADE FLOOR TILES
SIZE: 200 X 200
TF FLOOR TILES / /
FINISH: MATT / SLIP RESISTANT
COLOUR: GREY
COUNCIL ANNOTATION:
CERAMIC TILES
COMMERCIAL GRADE FLOOR TILES Exemption Certificate EXE25/0032
SIZE: 200 X 200
TW WALL TILES
FINISH: GLOSS
/ / only relates to the replacement of the
COLOUR: WHITE existing roof and upgrade of ground
NAME: TRIMDEK®
floor toilets from code assessment for
C2 Steel Thickness: .47 BMT LYSIGHT building works within the Medium
ROOFING
RC ROOF SHEETING ROOF
FINISH: ZINCALUME® steel. https://lysaght.com/profiles/trimdek Impact Industry Zone.
Gutter Overhang: 50mm recommended
NAME / CODE: DESIGNER WHITE
FINISH: TEXTURE JOINERY - POLYTEC
L1 LAMINATE
COLOUR: WHITE KITCHENETTE DOORS https://www.polytec.com.au
THICKNESS: 16mm
NAME / CODE: Aston White
LAMINATES
FINISH: Smooth JOINERY - POLYTEC
LB LAMINATE BENCH TOP
COLOUR: WHITE KITCHENETTE BENCH TOP https://www.polytec.com.au
Benchtop Thickness: 33mm
NOOSA COUNCIL
REFERENCE DOCUMENT
EXE25/0032 25 AUG 2025
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No.
sections of technical specification.
C2 TRIMDEK SPECIFIED AS .47 BMT 144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A040
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
FINISHES SCHEDULE Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C2
Version: 1, Version Date: 13/08/2025
Page 6
TENANCY T2: TENANCY T1:
CX
DEMOLISH EXISTING DEMOLISH EXISTING STAIR,
A B C D A201 E F G MEZZANINE TIMBER FLOOR H MEZZANINE FLOOR AND I
INTERNAL WALL PARTITIONS
TO BOTH LEVELS
54500
200 7450 150 7525 200 7375 150 7450 200 6000 200 6000 200 6000 200 5000 200
200 4550 2900 150 2900 4625 200 4475 2900 150 2900 4550 200 6000 200 6000 200 6000 200 5000 200
200
1
1100
1100
1100
1100
ME
Z
LEV ZANIN
EL
OVE E
R
ALLOW FOR REMOVAL OF EXISTING
6000
REMOVE EXISTING TOILET AND REMOVE EXISTING TOILET AND TOILETS AND KITCHENETTES FROM
KITCHENETTE. MAKE FLOORS & KITCHENETTE. MAKE FLOORS & TENANCIES T1; T2; T3 & T4.
ME
WALLS GOOD TO RECEIVE NEW WALLS GOOD TO RECEIVE NEW CONFIRM LAYOUT AND LOCATION
ZZA
8700
FINISH AS SPECIFIED FINISH AS SPECIFIED ON SITE MAKE FLOORS & WALLS
N IN
EL
GOOD TO RECEIVE NEW FINISH AS
EV
SPECIFIED
EL
12000
12000
12000
2
OV
ER
Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy
T8 T7 T6 T5 T4 T3 T2 T1
15600
GLA = 161 m² GLA = 157 m² GLA = 136 m² GLA = 119 m² GLA = 74 m² GLA = 74 m² GLA = 74 m² GLA = 44 m²
14500
18000
6400
DP
16900
REMOVE EXISTING
DOORS & WINDOWS
20400
BX DP
19300
19300
FHR
A201 REMOVE EXISTING REMOVE EXISTING REMOVE EXISTING
23200
22800
ROLLER DOOR ROLLER DOOR ROLLER DOOR
Roller Door Roller Door Roller Door
3
DP DP DP DP DP DP DX
A202
REMOVE EXISTING
SB
DOORS & SHOPFRONT
REMOVE EXISTING
ROLLER DOOR Existing Palm Tree
6000
SB Roller Door
SB
DP
Awning Over
REMOVE EXISTING Roof Over
ROLLER DOOR
SB Roller Door
REMOVE EXISTING
4 DOORS & SHOPFRONT DP Awning Over
FHR
REMOVE EXISTING REMOVE EXISTING Roof Over
ROLLER DOOR ROLLER DOOR
Roller Door Roller Door
4800
DP DP REMOVE EXISTING
Awning Over
2400
Roof Over EXTERNAL AWNINGS
200
5 DP
Awning Over
Roof
Over
AX
A200
COUNCIL ANNOTATION:
Exemption Certificate EXE25/0032
DEMOLITION NOTES: 4. Remove existing RSD’s and shopfronts. only relates to the replacement of the
1. All demolition work, including asbestos removal, 5. Remove existing internal office walls. existing roof and upgrade of ground
NOOSA COUNCIL shall be carried out by a suitably licensed and 6. Remove existing signage.
floor toilets from code assessment for
competent sub-contractor. The works included are 7. Remove existing damaged DP’s, gutters and facias.
REFERENCE DOCUMENT limited to the following items. 8. Remove existing external awnings.
building works within the Medium
A FLOOR PLAN: EXISTING & DEMOILITION EXE25/0032 25 AUG 2025 2. Remove all asbestos as identified in QBM Asbestos 9. Remove existing brick paving to unit entries. Impact Industry Zone.
Scale 1:150 @ A3 Materials Report and Register dated 12/07/2022. 10. Remove & replace existing fire hose reels
-
3. Remove existing landscaping and tress.
REFER TO DRAWING A040 FOR FINISHES SCHEDULE
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No. north
sections of technical specification.
144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
N
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A100
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
FLOOR PLAN: EXISTING & DEMOLITION Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C1
Version: 1, Version Date: 13/08/2025
Page 7
01
A300
A B C D E F G H I
7725 7700 7550 7725 6100 6200 6200 5300
200 4400 105 2800 440 2800 105 4475 200 4325 105 2800 440 2800 105 4400 200 3000 105 2800 390 2800 105 3000 200 3000 105 2800 390 2800 105 2000 200
1
110
2075
D01
D02
D03
D04
D05
D06
D07
D08
105
6000
PROVIDE ALL NEW TOILET PROVIDE ALL NEW TOILET PROVIDE ALL NEW TOILET PROVIDE ALL NEW TOILET PROVIDE ALL NEW TOILET PROVIDE ALL NEW TOILET PROVIDE ALL NEW TOILET
AND KITCHENETTE. AND KITCHENETTE. AND KITCHENETTE. AND KITCHENETTE. AND KITCHENETTE. AND KITCHENETTE. AND KITCHENETTE.
NEW CONCRETE
BLOCKWORK WALL TO INFILL
2 EXISTING OPENING IN WALL
Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy
T8 T7 T6 T5 T4 T3 T2 T1
GLA = 161 m² GLA = 157 m² GLA = 136 m² GLA = 119 m² GLA = 74 m² GLA = 74 m² GLA = 74 m² GLA = 44 m²
200 SB 5000 200
200 7470 110 7590 110 7440 150 7470 200 6000 200 6000 200 6000
6400
SUPPLY & INSTALL NEW DP
DOORS & SHOPFRONT
DP TS
FHR
SUPPLY & INSTALL SUPPLY & INSTALL SUPPLY & INSTALL 1150
18110
NEW ROLLER DOOR NEW ROLLER DOOR NEW ROLLER DOOR
3
DP DP DP DP DP DP D
TS TS A202
SUPPLY & INSTALL NEW TS 1500
SB 4700
DOORS & SHOPFRONT
SUPPLY & INSTALL TS: DOUBLE FACES WALL MOUNTED SUPPLY & INSTALL
NEW ROLLER DOOR Existing Palm Tree INTERNALLY ILLUMINATED NEW DOOR & WINDOW
6000
SB TENANCY SIGN TO EACH
SB
TENANCY BY LESSOR.
DP SIGN FACES BY LESSEE.
SUPPLY & INSTALL TS Roof Over PROVIDE POWER AS REQUIRED
NEW ROLLER DOOR
SB 900
SUPPLY & INSTALL NEW
4 DOORS & SHOPFRONT DP
FHR
SUPPLY & INSTALL SUPPLY & INSTALL TS Roof Over
NEW ROLLER DOOR NEW ROLLER DOOR
900
4800
DP DP NEW EXTERNAL COUNCIL ANNOTATION:
Roof Over AWNINGS
TS Exemption Certificate EXE25/0032
5300 only relates to the replacement of the
5 DP 1500
existing roof and upgrade of ground
NOOSA COUNCIL floor toilets from code assessment for
Roof TS
Over A FLOOR PLAN: PROPOSED A REFERENCE DOCUMENT building works within the Medium
01 A200 EXE25/0032 25 AUG 2025 Impact Industry Zone.
- Scale 1:150 @ A3
A300
PROPOSED SCOPE OF WORKS: PROPOSED SCOPE OF WORKS: GLA ING PROPOSED SCOPE OF WORKS: PROPOSED SCOPE OF WORKS: PROPOSED SCOPE OF WORKS: METAL WORK PROPOSED SCOPE OF WORKS: CARPENTRY & OINERY PROPOSED SCOPE OF WORKS: CERAMIC TILES PROPOSED SCOPE OF WORKS: PAINTING
1. Provide new landscaping and trees as per Remove and replace all existing doors and HYDRAULICS PARTITIONS & CEILINGS All works will be carried out to Australian All works will be carried out to Australian Standards, the All works will be carried out to Australian All works will be carried out to Aus. Standards and manufacturers
landscape architect drawings windows with powder coated (from All plumbing and drainage to be carried out All works will be accurately set out in accordance Standards and manufacturers works include and are limited to: Standards, the works include and are limited to: recommendations, the works include and are limited to:
2. Supply and install new RSD’s and standard Dulux powder coat colour range) to Australian Standards and Hydraulic with the Architects design documents and works recommendations, the works include and are Supply & install paint finish hollow core internal doors, Wall tiles: Supply and fix 200x200 white ceramic Plaster board seal and 2 coats of Dulux low sheen paint, doors to be
shopfronts. aluminum window frames 100x42 Engineers design, the works include and are carried out to Australian Standards and limited to the following items, all doors fitted with brushed satin commercial grade tiles, 1 row above hand basins, 1 row as skirting. sealed and 2 coats of Dulux semi-gloss paint.
sections including doors. Commercial limited to the following areas, manufacturers recommendations, the works Supply and install into wall construction hardware, as per BCA and Australian Standards. Floor tiles: Supply and lay 200x200 grey ceramic
3. Supply and install new signage. Internal walls to be cleaned sealed and 2 coats of low sheen paint.
grade door furniture to comply with the Supply all under slab drainage and water include and are limited to the following areas pressed metal door frames to sizes indicated Supply and install 4kg fire extinguishers including tiles.
4. Supply and install new DP’s, gutters and South and east elevations external building walls to be rendered and
BCA. All glass to comply with relevant supply to the new disabled compliant WC to 1. Metal stud walls 75mm lined with 10mm on drawings. signage as required by the BCA.
facias. new textured paint, primed and 2 Coats of Dulux paint to be applied
Australian Standards. each tenancy and the adjacent kitchen sink flush set plaster board to new WC amenities Supply and install disabled handrails, toilet roll Supply and install 1500mm long kitchen unit to each PROPOSED SCOPE OF WORKS: FLOOR FINISHES
5. Supply and install new external awnings. as per manufacturer’s specifications.
unit. area to each tenancy holders, paper towel dispensers as required by tenancy complete with 900mm stainless steel sink. Prepare and apply industrial epoxy resin to
6. Provide new paving to unit entries. Replace existing fire hose reels 2 no. 2. Suspended flush plaster board ceiling linings Building Code of Australia. tenancy floors.
7. Supply and install new roller doors. to the amenities only. REFER TO DRAWING A040 FOR FINISHES SCHEDULE
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No. north
sections of technical specification.
144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
N
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A101
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
FLOOR PLAN: PROPOSED Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C1
Version: 1, Version Date: 13/08/2025
Page 8
A B C D E F G H I
PD1 T PICAL
-
EXISTING WALL
1
NEW STEEL STUD WALL, NEW STEEL STUD WALL, NEW STEEL STUD WALL, NEW STEEL STUD WALL,
PBD LINED TO BOTH SIDES, PBD LINED TO BOTH SIDES, PBD LINED TO BOTH SIDES, PBD LINED TO BOTH SIDES,
FINISH AS SPECIFIED FINISH AS SPECIFIED FINISH AS SPECIFIED FINISH AS SPECIFIED
2
Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy
T8 T7 T6 T5 T4 T3 T2 T1
GLA = 161 m² GLA = 157 m² GLA = 136 m² GLA = 119 m² GLA = 74 m² GLA = 74 m² GLA = 74 m² GLA = 44 m²
SB
3
COUNCIL ANNOTATION:
Exemption Certificate EXE25/0032
only relates to the replacement of the
existing roof and upgrade of ground
floor toilets from code assessment for
building works within the Medium
GRID
4
EXISTING WALL Impact EXISTING
IndustryWALL Zone.
2990 250 2990
50 50
75 2840 75 150 75 2840 75
NOTE:
NEW WALLS ARE DIMENSIONED TO FACE OF
75
75
75
NEW STEEL STUD WITHOUT WALL LININGS.
75
NEW 75mm METAL
NEW 75mm METAL STUD WALL NEW 75mm METAL STUD WALL
NEW 75mm METAL
ALLOW FOR FINISHES AS SPECIFIED
STUD WALL
STUD WALL
NEW 75mm METAL STUD WALL
NEW 75mm METAL STUD WALL
5
1065
1065
NOTE:
NEW WALLS CONSTRUCTION TO BE METAL
A FLOOR PLAN: SETUP PLAN STUD WALLS 75mm LINED WITH 10mm
2270
2120
2120
2270
FLUSH SET PLASTER BOARD TO BOTH SIDES
- Scale 1:150 @ A3
DOOR OPENING
DOOR OPENING
NEW DOOR
NEW DOOR
960
960
75 95
75 95
75
75
NEW 75mm METAL STUD WALL NEW 75mm METAL STUD WALL
NOOSA COUNCIL 75 2965 150 2965 75
3040 3040
REFERENCE DOCUMENT
EXE25/0032 25 AUG 2025 PD1 TYPICAL PLAN SETUP DETAIL
- Scale 1:50 @ A3
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No. north
sections of technical specification.
144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
N
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A102
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
FLOOR PLAN: SETUP PLAN Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C1
Version: 1, Version Date: 13/08/2025
Page 9
A B C D E F G H I
7725 7700 7550 7725 6100 6200 6200 5300
NEW ACCESSIBLE TOILETS: WALL FLOOR FINISHES NEW ACCESSIBLE TOILETS: WALL FLOOR FINISHES
WALL TILES: SUPPLY AND FIX 200X200 WHITE CERAMIC TILES, WALL TILES: SUPPLY AND FIX 200X200 WHITE CERAMIC TILES,
1 ROW ABOVE HAND BASINS, 1 ROW AS SKIRTING. 1 ROW ABOVE HAND BASINS, 1 ROW AS SKIRTING.
FLOOR TILES: SUPPLY AND LAY 200X200 GREY CERAMIC TILES. FLOOR TILES: SUPPLY AND LAY 200X200 GREY CERAMIC TILES.
NOTE: REFER TO AMENITIES DRAWINGS FOR FURTHER DETAILS NOTE: REFER TO AMENITIES DRAWINGS FOR FURTHER DETAILS
1
ATR
ATR
ATR
ATR
ATR
ATR
ATR
ATR
6000
PREPARE AND APPLY EPOXY
RESIN TO TENANCY FLOOR
2
FE
Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy Tenancy
T8 T7 T6 T5 T4 T3 T2 T1
GLA = 161 m² GLA = 157 m² GLA = 136 m² GLA = 119 m² GLA = 74 m² GLA = 74 m² GLA = 74 m² GLA = 44 m²
SB
PREPARE AND APPLY EPOXY PREPARE AND APPLY EPOXY PREPARE AND APPLY EPOXY PREPARE AND APPLY EPOXY PREPARE AND APPLY EPOXY PREPARE AND APPLY EPOXY PREPARE AND APPLY EPOXY
6400
RESIN TO TENANCY FLOOR RESIN TO TENANCY FLOOR RESIN TO TENANCY FLOOR RESIN TO TENANCY FLOOR RESIN TO TENANCY FLOOR RESIN TO TENANCY FLOOR RESIN TO TENANCY FLOOR
FE FE FE FE FE FE FE
3
6000
4
COUNCIL ANNOTATION:
Exemption Certificate EXE25/0032
only relates to the replacement of the
4800
existing roof and upgrade of ground
floor toilets from code assessment for
building works within the Medium
5 Impact Industry Zone.
A FLOOR PLAN: PROPOSED FLOOR FINISHES
- Scale 1:150 @ A3
PROPOSED SCOPE OF WORKS: CERAMIC TILES
All works will be carried out to Australian ATR:
Standards, the works include and are limited to: ALUMINIUM TRANSITION STRIP
Wall tiles: Supply and fix 200x200 white ceramic PROVIDE TRANSITION STRIP AS
REQUIRED AT TRANSITION OF 2
tiles, 1 row above hand basins, 1 row as skirting.
DIFFERENT FLOOR FINISHES
Floor tiles: Supply and lay 200x200 grey ceramic
tiles.
NOOSA COUNCIL
PROPOSED SCOPE OF WORKS: FLOOR FINISHES
REFERENCE DOCUMENT Prepare and apply grey epoxy paint to tenancy
EXE25/0032 25 AUG 2025 floors.
REFER TO DRAWING A040 FOR FINISHES SCHEDULE
PROJECT ISSUE: FOR CONSTRUCTION
GENERAL NOTES No. AMENDMENT DATE IN ASSOCIATION WITH: project :
Architectural documents to be read in conjunction with relevant Structural, Fire Service, Mechanical, Hydraulic, JANE PROPERTY
Electrical, Civil and Landscaping documents. Technical drawings to be read in conjunction with appropriate C1 TITLE BLOCK REVISED; ISSUED FOR CONSTRUCTION 09.12.2024 Project No. Drawing No. north
sections of technical specification.
144 Eumundi Noosa Rd, Noosaville QLD 4566 address : AS74
N
Contractor to verify all dimensions / condition on site prior to commencement of works. Contractor to seek
Total Area
clarification of all inconsistencies and resolve all discrepancies on plans and site conditions prior to
description : - A105
commencement of any works on site. Commencement of works on site by the contractor is deemed to be
acceptance of all conditions and plans and any variations will be the responsibility of the contractor expense. INTERNATIONAL First Drawn Scale Revision
Figured dimensions shall take precedence to scaled dimensions. TOTAL PROPERTY DEVELOPMENT SOLUTIONS drawing title : September 2024
Copyright of designs shown herein is retained by Allister Sarris. Written authority is required for any reproduction.
FLOOR PLAN: FLOOR FINISHES Date Issued Paper Size
Notify SARRIS ARCHITECTURE of any changes. No changes to occur without SARRIS approval.
Document Set ID: 24027286 CHECKED BY: S.E. HARDY (QBSA LICENCE NUMBER 65539) - A3 C1
Version: 1, Version Date: 13/08/2025