Council archive · source document
Decision Notice - 010.2006.00002554.001 [As Published] · 132006.2554
NOOSA COUNCIL IDAS Development Application Decision Notice 3 of 11
Noosa Council Conditions
INTEGRATED PLANNING ACT 1997, IDAS DEVELOPMENT APPLICATION
Land Use
1. Development undertaken in accordance with this approval must generally comply with the approved plans
of development. The approved plans are titled and numbered
Site Plans, PD-02
Existing Levels, PD-03
Basement Floor Plan, PD-04
Ground Floor Plan, PD-05
First Floor Plan, PD-06
Front & Rear Elevations, PD-07
Side Elevations, PD-08
prepared by John Murchie and dated August 2006 and as may be amended by these conditions.
2. The development must be undertaken and operated in a manner that causes no detrimental effect upon
the amenity of the neighbourhood by reason of the creation of excessive noise, lighting nuisance or other
emissions.
3. The rear property boundary fence must comply with the following requirements:
3.1. no more than 1.2m in height; and
3.2. be of open construction (ie at least 50% transparent); and
3.3. be constructed with lightweight materials (ie timber); and
3.4. be of dark colours to blend with the natural landscape.
4. Gates must not be installed along the rear property boundary.
5. Dense landscaping, comprising a mix of native coastal species of ground cover, scrubs and trees, is
provided for a width of 5m from the seawards or rear boundary of the site to provide adequate landscape
buffering to protect the coastal dune system.
It is noted that the 3000lt rainwater storage tank may need to be relocated to comply with this
requirement.
6. The boat storage shed must comply with the following requirements:
6.1 Have a length no greater than 9m
6.2 Have a maximum height not greater than 4.5m and a mean height not greater than 3.5m as
defined in the Queensland Development Code Part 12 – Design and Siting Standard for Single
Detached Housing – on lots 450m² and over.
7. Plans showing compliance with Condition 6 are to be submitted to Council, prior to obtaining a
Development Permit for Building Works.
8. All hot water systems installed shall be either solar systems; electric heat pump systems; or gas systems
(LPG or natural).
9. A rainwater storage tank with a minimum capacity of 3000 litres shall be provided on site to service the
detached house. The tank is to be installed to ensure water from the tank can be used both:
9.1 for external use such as watering gardens, irrigation, ornamental ponds or water features, topping
up swimming pools, outdoor cleaning; and
9.2 for use in flushing of toilets internal to the building.
A c:\docume~1\dwallace\locals~1\temp\bcl technologies\easypdf 5\@bcl@200430cf\@[email protected]
See the original