Original source · versioned page text
Approved Plan - Landscape Specification prepared by URBIS - OPW24/0110
Treatment, natural durability classes and combinations thereof shall conform to AS 1604, TUMA (Timber
Utilisation and Marketing Act Qld 1987) and TMA (Timber Marketing Act NSW 1977).
A certification of treatment shall be provided.
Timber pavement finish
Where timber is used as a floor finish ensure timber decking coating comply with the slip resistance
requirements of the National Construction Code (NCC) and Australian Standards AS/NZS 4586 2013, AS
HB 198 2014. Provide complying slip resistance test results to the Superintendent.
9.3. CONCRETE WORKS
General
This specification sections applies for insitu-concrete and pre-cast concrete elements.
All components of concrete works such as concrete mix, water-cement ratio, concrete strength, pigment
quantities, formwork types, release agent, sand type and sealer shall be kept consistent throughout the
project to avoid differences between the elements.
Regulatory Standards & Industry Association Reference Publications
The relevant Industry Association reference publications and guide standards should be use for the relevant
work:
• CCAA Cement Concrete & Aggregates Australia www.concrete.net.au
• CCAA Guides series, including the following as applicable:
• CCAA T57 Guide to Off-Form Concrete Finishes
• CCAA T59 Guide to Concrete Flatwork Finishes
• CCAA Data Sheets series, including the following as applicable:
• CCAA Data Sheet – Avoiding Surface Imperfections in Concrete
• CCAA Data Sheet – Removing Stains from Concrete
• CCAA Data Sheet – Cleaning Concrete
• NPCAA - Precast Concrete Handbook
• AS 3610 – Formwork for Concrete
• AS 3600 – Concrete Structures
• AS 1379 – Specification and Supply of Concrete
• Local Authorities Applicable Regulations
• Building Code of Australia including Standards referenced in the NCC/BCA.
9.4. PAVEMENT PROFILES – CONCRETE
PA01: Pavement Profile –Concrete – On Grade – BY CIVIL
Material – In-situ concrete. 125mm thickness. Normal class. Minimum grade N32.
Supplier – Boral or approved equivalent.
Colour – Grey cement
Surface Finish – Broomed. Apply finish after control joints have been tooled
Slip rating – Wet Pendulum Class rating ‘P4’ and slip resistant R11. All areas steeper than 1:14 to be Wet
Pendulum Class rating ‘P5’ and slip resistant R12.
Sealer – Penetration, non-yellowing protective sealer for concrete floors. CCS Streetscape or approved
equivalent.
URBIS
URB-P0003847-000-SP.DOCX PAGE 14
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.