4.4    WBNM Analysis Pre-Development Scenario


A WBNM was approximated for the existing catchments according to existing site parameters.
The model estimated that the existing 1% AEP peak flow discharge from the site was
0.8m3/s overall. Pre-development peak flow rates for all design storms are provided in Table
4-4.


                                         EXISTING CASE - COMBINED
                                                Peak Flow Rates - Q (m3/s)
                          AEP             WBNM             RM           Difference
                         63.2%            0.197           0.209             6.1%
                          50%             0.242           0.277            14.5%
                          20%             0.457           0.384           -16.0%
                          10%             0.485           0.465            -4.1%
                          5%              0.578           0.552            -4.5%
                          2%              0.725           0.704            -2.9%
                          1%              0.801           0.807             0.7%
                         Table 4-4 WBNM discharge flow rates for pre-development catchments




The Rational Method was used to provide an estimate of a range of flows for the total pre-
development catchment for comparison and verification of the WBNM model. See Appendix
D for calculations. The Rational Method results are within 20% of the results obtained from
the WBNM analysis for the pre-development case across all storm events. From the
comparison of results, it is determined that the Rational Method verification corresponds well
with the WBNM analysis results.




2576-SBSMP-01_Version 2.0 (April 2026)                                                        Page 17 of 23
SX/TB

Log in to download the original (RFI (rec. 5.06.26) 2567 - Appendix B - Site-Based Stormwater Management Plan (SBSMP) (Ver. 2).pdf)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.