Appendix C - Engineering Plans
Attached to the e-mail Response to Council's Request for Information (REC17 /0011) - Email 01 of 01.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnHaynes Consulting Engineers Pty Ltd
ABN No. 53613630078
P.O Box 549 Noosa Heads 4567
Ph: 0432 784 150
27th June 2017 File No: 1702
Noosa Shire Council
(by email)
Attention: Mark Lewis
Dear Sir,
REC17/0011 – Eagle Rise Subdivision, Eagle Drive, Tewantin
We are responding to engineering matters raised in your information request letter dated 21-
4-17, and enclose IWMP Rev1 and plans 1702-01B, 1702-02A to 1702-07A inclusive.
1 Consistent layout plans with Stormwater
We enclose plan 1702-01B to show Murrays lot layout matching stormwater master plans.
2 Turn area for subdivision stages
We enclose plan 1702-07A with appropriate sealed turn areas for a garbage truck as per
section 2.9 of PSP5. The concept is to have trucks entering one driveway in a forward
direction and use verge when reversing. An easement over property is proposed to maintain
access until adjacent subdivision is created and turn area is not required.
3 Lot 7 access
Access to lot 7 and 8 is via a concrete driveway that will be constructed as part of
subdivision works in an access handle, refer to plan 1702-01B. Therefore no works in road
reserve to north of lots 7 and 8 is required.
4 Lot 12-16 Frontage work
The existing verge at frontages of lots 12-18 is not far above existing top of kerb level. To
obtain road flows to QUDM requirements the verge needs raising to 100mm above top of
kerb level.
As per plans 1702-01B and 1702-02A the works include:
Footpath and verge re-shaping,
Installation of stormwater pipe from subdivision to bio/detention basin,
Adjustments to driveway levels at no 12, 16, 18 Eagle drive to obtain required height
(design and permission to be obtained as part of Operational Works).
5 Stormwater Management Plan
Please note enclosed Integrated Water Management Plan Revision 1 (IWMP Rev 1),
specifically Section 2.0 which responds to Information Request.
C:\APROJECTS\1702 Eagle Drive\CORROUT\REC reply.docx
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.
Full text of the other 8 pages
Page 2
6 Stormwater Easements Please see plan 1702-01B which shows stormwater easements. 7 Preliminary Road Design We enclose plans 1702-01B and plans 1702-04A to 1702-06A which show preliminary road design. To provide a suitable house site on low lots minor fill will be placed generally as shown with 1:6 batter to natural surface. Overall slope is away from road as per existing ground and roofwater pits will be placed at low side of lots. Yours faithfully, A Haynes BE Civil (Hons) MIE Aust RPEQ CPEng CC Eagle Rise Developments Pty Ltd C:\APROJECTS\1702 Eagle Drive\CORROUT\REC reply.docx
Page 3
POST DEVELOPMENT INTERNAL CATCHMENT B TO BE TREATED
IN BIO-RETENTION A=0.529Ha. AREA ALSO TO BE TREATED IN
DETENTION. AS THESE AREA DO NOT FLOW TO BASIN PART OF POST DEVELOPMENT INTERNAL
EXTERNAL CATCHMENT WILL BE TREATED INSTEAD. CATCHMENT A TO EAGLE DRIVE
EXTENSION A=1.056Ha
EXISTING HOUSE WITH
ROOFWATER TO TAIT STREET, EXTERNAL CATCHMENT C TO EAGLE
UNCHANGED AND NOT PART DRIVE EXTENSION. IF DEVELOPED
OF TREATMENT AREA OTHERS TO TREAT WATER QUALITY
AND DETENTION.
NEW ROOFWATER ONLY PIPE
TO TAIT STREET STORMWATER
SYSTEM (NO OVERLAND FLOW)
S
SW
+ +
OVERALL
DEVELOPED
EXTERNAL
CATCHMENT CERTIFIED BY:
F TO 14
EAGLE RPEQ No.: 13201 (Allister Haynes)
DRIVE AS DATE: 19/6/2017
PER
COUNCIL
MASTER
DRAINAGE
CATCHMENTS.
E
D
PSM No -
HAYNES CONSULTING ENGINEERS EAGLE DRIVE - TEWANTIN
C
(AHD) RL -
ABN 53 613 630 078 RECONFIGURATION INFORMATION RESPONSE 1702
B 27-6-17 REVISED REAR BDY LOTS 14/15 ATH SURVEYED -
PO BOX 549 NOOSA HEADS QLD 4567 PROPOSED SUBDIVISION 20 EAGLE DRIVE Sheet No. - Revision No.
A 11-6-17 FOR APPROVAL ATH
Rv DATE REVISIONS APPR.
(0432) 784 150
STORMWATER LAYOUT PLAN 01 B
Page 4
S
SW
+ +
CERTIFIED BY:
RPEQ No.: 13201 (Allister Haynes)
DATE: 19/6/2017
E
D
PSM No -
HAYNES CONSULTING ENGINEERS EAGLE DRIVE - TEWANTIN
C
(AHD) RL -
ABN 53 613 630 078 RECONFIGURATION INFORMATION RESPONSE 1702
B SURVEYED -
PO BOX 549 NOOSA HEADS QLD 4567 PROPOSED SUBDIVISION 20 EAGLE DRIVE Sheet No. - Revision No.
A 11-6-17 FOR APPROVAL ATH
Rv DATE REVISIONS APPR.
(0432) 784 150
BIO/DETENTION LAYOUT PLAN 02 A
Page 5
CERTIFIED BY:
RPEQ No.: 13201 (Allister Haynes)
DATE: 19/6/2017
E
D
PSM No -
HAYNES CONSULTING ENGINEERS EAGLE DRIVE - TEWANTIN
C
(AHD) RL -
ABN 53 613 630 078 RECONFIGURATION INFORMATION RESPONSE 1702
B SURVEYED -
PO BOX 549 NOOSA HEADS QLD 4567 PROPOSED SUBDIVISION 20 EAGLE DRIVE Sheet No. - Revision No.
A 12-6-17 FOR APPROVAL ATH 1702
Rv DATE REVISIONS APPR.
(0432) 784 150
BIO/DETENTION SECTION PLAN 03 A
Page 6
CERTIFIED BY:
RPEQ No.: 13201 (Allister Haynes)
DATE: 19/6/2017
E
D
PSM No -
HAYNES CONSULTING ENGINEERS EAGLE DRIVE - TEWANTIN
C
(AHD) RL -
ABN 53 613 630 078 RECONFIGURATION INFORMATION RESPONSE 1702
B SURVEYED -
PO BOX 549 NOOSA HEADS QLD 4567 PROPOSED EXTENSION OF EAGLE DRIVE Sheet No. - Revision No.
A 12-6-17 FOR APPROVAL ATH
Rv DATE REVISIONS APPR.
(0432) 784 150
LONG SECTION PLAN 04 A
Page 7
CERTIFIED BY:
RPEQ No.: 13201 (Allister Haynes)
DATE: 19/6/2017
E
D
PSM No -
HAYNES CONSULTING ENGINEERS EAGLE DRIVE - TEWANTIN
C
(AHD) RL -
ABN 53 613 630 078 RECONFIGURATION INFORMATION RESPONSE 1702
B SURVEYED -
PO BOX 549 NOOSA HEADS QLD 4567 PROPOSED EXTENSION OF EAGLE DRIVE Sheet No. - Revision No.
A 12-6-17 FOR APPROVAL ATH 1702
Rv DATE REVISIONS APPR.
(0432) 784 150
CROSS SECTION PLAN 1 05 A
Page 8
CERTIFIED BY:
RPEQ No.: 13201 (Allister Haynes)
DATE: 19/6/2017
E
D
PSM No -
HAYNES CONSULTING ENGINEERS EAGLE DRIVE - TEWANTIN
C
(AHD) RL -
ABN 53 613 630 078 RECONFIGURATION INFORMATION RESPONSE 1702
B SURVEYED -
PO BOX 549 NOOSA HEADS QLD 4567 PROPOSED EXTENSION OF EAGLE DRIVE Sheet No. - Revision No.
A 12-6-17 FOR APPROVAL ATH 1702
Rv DATE REVISIONS APPR.
(0432) 784 150
CROSS SECTION PLAN 2 06 A
Page 9
CERTIFIED BY:
RPEQ No.: 13201 (Allister Haynes)
DATE: 19/6/2017
E
D
PSM No -
HAYNES CONSULTING ENGINEERS EAGLE DRIVE - TEWANTIN
C
(AHD) RL -
ABN 53 613 630 078 RECONFIGURATION INFORMATION RESPONSE 1702
B SURVEYED -
PO BOX 549 NOOSA HEADS QLD 4567 PROPOSED SUBDIVISION 20 EAGLE DRIVE Sheet No. - Revision No.
A 11-6-17 FOR APPROVAL ATH
Rv DATE REVISIONS APPR.
(0432) 784 150
TURN PATH LAYOUT 07 A